S3125

Sigma-Aldrich

Bis(2-ethylhexyl) sebacate

~95%

동의어(들):

Di(2-ethylhexyl) sebacate, Sebacic acid di(2-ethylhexyl) ester, ‘Dioctyl’ sebacate

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
[-(CH2)4CO2CH2CH(C2H5)(CH2)3CH3]2
CAS Number:
Molecular Weight:
426.67
Beilstein:
1806504
EC Number:
MDL number:
UNSPSC 코드:
12352211

분석

~95%

refractive index

n20/D 1.450 (lit.)

bp

212 °C/1 mmHg (lit.)

density

0.914 g/mL at 25 °C (lit.)

저장 온도

2-8°C

SMILES string

CCCCC(CC)COC(=O)CCCCCCCCC(=O)OCC(CC)CCCC

InChI

1S/C26H50O4/c1-5-9-17-23(7-3)21-29-25(27)19-15-13-11-12-14-16-20-26(28)30-22-24(8-4)18-10-6-2/h23-24H,5-22H2,1-4H3

InChI key

VJHINFRRDQUWOJ-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

교체됨

제품 번호
설명
가격

Storage Class Code

10 - Combustible liquids

WGK

awg

개인 보호 장비

Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

D Oesterle et al.
Journal of cancer research and clinical oncology, 114(2), 133-136 (1988-01-01)
The plasticizer DEHP but not DEHS exerted a weak promoting effect in a 12-week rat liver foci bioassay, using weanling female Sprague-Dawley rats. The effect was similar after doses of 200 and 500 mg/kg body weight, given 3 times weekly
Kevin R Wilson et al.
Physical chemistry chemical physics : PCCP, 14(4), 1468-1479 (2011-12-14)
The heterogeneous reactions of hydroxyl radicals (OH) with squalane and bis(2-ethylhexyl) sebacate (BES) particles are used as model systems to examine how distributions of reaction products evolve during the oxidation of chemically reduced organic aerosol. A kinetic model of multigenerational
Nedime Dürüst et al.
Analytica chimica acta, 699(1), 107-112 (2011-06-28)
Polycation-sensitive membrane optodes based on the chromoionophore 2',7'-dichlorofluorescein octadecylester (DCFOE) have previously been developed and used for determination of heparin via a titrimetric method. In this study, it is shown that some other important polyanions such as PPS (pentosan polysulfate)
M Kohlhäufl et al.
American journal of respiratory and critical care medicine, 159(3), 902-906 (1999-03-02)
Previous studies suggest that lung function tests using monodisperse aerosols can help to identify early stages of lung diseases. We investigated intrapulmonary particle loss and aerosol bolus dispersion-a marker of convective gas transport-in 32 women with asymptomatic nonspecific bronchial hyperresponsiveness
C S Kim et al.
Journal of applied physiology (Bethesda, Md. : 1985), 81(5), 2203-2213 (1996-11-01)
Detailed regional deposition of inhaled particles was investigated in young adults (n = 11) by use of a serial bolus aerosol delivery technique. A small bolus (45 ml half-width) of monodisperse aerosols [1-, 3-, and 5-microns particle diameter (Dp)] was