콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

N6264

Sigma-Aldrich

Neutral Red Solution, Buffered

동의어(들):

Neutral Red solution, 3-Amino-7-dimethylamino-2-methylphenazine hydrochloride, Toluylene red

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C15H17ClN4
CAS Number:
Molecular Weight:
288.78
MDL number:
UNSPSC 코드:
12171500
PubChem Substance ID:
NACRES:
NA.47

형태

solution

유통기한

Expiry date on the label

IVD

for in vitro diagnostic use

농도

0.5% (w/v, acetate buffer, pH 5.2. Preservative added.)

pH

5.2

응용 분야

hematology
histology

저장 온도

room temp

SMILES string

[Cl-].Cc1cc2N=C3C=C\C(C=C3Nc2cc1N)=[N+](/C)C

InChI

1S/C15H16N4.ClH/c1-9-6-13-15(8-11(9)16)18-14-7-10(19(2)3)4-5-12(14)17-13;/h4-8H,16H2,1-3H3;1H

InChI key

PGSADBUBUOPOJS-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Used as a red nuclear counterstain in various cytochemical procedures.

픽토그램

Exclamation markEnvironment

신호어

Warning

유해 및 위험 성명서

Hazard Classifications

Aquatic Chronic 2 - Skin Sens. 1

Storage Class Code

12 - Non Combustible Liquids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, multi-purpose combination respirator cartridge (US)


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Devis Bellucci et al.
Materials (Basel, Switzerland), 12(13) (2019-07-03)
Bioactive glasses (BGs) are currently employed in a wide range of medical and dentistry applications by virtue of their bone-bonding ability. The incorporation of BGs into a collagen matrix may be used to combine the regenerative potential of these materials
Devis Bellucci et al.
Materials science & engineering. C, Materials for biological applications, 96, 757-764 (2019-01-05)
A novel bioglass composition (BGMS10), containing strontium and magnesium and characterized by an ultra-high crystallization temperature, is here employed for the first time to produce different composites with the addition of specific amounts of hydroxyapatite. After an investigation of the
Robim M Rodrigues et al.
Toxicology in vitro : an international journal published in association with BIBRA, 27(2), 760-767 (2012-12-25)
When in vitro test systems are evaluated for assessment of the toxicity of chemical compounds, particular efforts are made to mimic the in vivo reality as close as possible. Cellular models with appropriate metabolic competence, i.e. with the potency to
Kun Guo et al.
Biosensors & bioelectronics, 47, 184-189 (2013-04-13)
This study introduces a novel and simple method to covalently graft neutral red (NR) onto carbon surfaces based on spontaneous reduction of in situ generated NR diazonium salts. Immobilization of neutral red on carbon surface was achieved by immersing carbon
Cássio do Nascimento et al.
Microscopy research and technique, 76(2), 126-132 (2012-10-31)
The aim of this randomized crossover investigation was to assess the biofilm formation on two titanium and one zirconia substrates in relation to the topography and surface roughness of the materials. Twenty-four discs specimens for each evaluated material (Machined pure

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.