추천 제품
생물학적 소스
human cell culture
포장
pkg of 1 ea cell microarray block (HCL006)
pkg of 2 slides (HCL004)
pkg of 5 slides (HCL005)
제조업체/상표
Histocyte
저장 온도
2-8°C
일반 설명
The HPV/p16 Analyte Control has three cell line cores which demonstrate high, medium, and negative expression of high risk human papillomavirus (HPV) types 16 and 18. The same cell lines also demonstrate high homogenous, high heterogenous, and negative expression of p16.
HistoCyte Laboratories control slides and blocks are made from cultured human cell lines to provide the required range of expression of a specific biomarker. The cell lines are processed using proprietary methods that allow for the creation of a high density embedded cell block with cores that retain their cellular morphology. Available as pre-cut unstained slides or as cell microarray blocks for sectioning.
HistoCyte Laboratories control slides and blocks are made from cultured human cell lines to provide the required range of expression of a specific biomarker. The cell lines are processed using proprietary methods that allow for the creation of a high density embedded cell block with cores that retain their cellular morphology. Available as pre-cut unstained slides or as cell microarray blocks for sectioning.
애플리케이션
Ideal for use as a same slide control for HPV in situ hybridization (ISH) and p16 immunohistochemistry (IHC).
The HPV/p16 Analyte Control histology slides have three cell line cores providing a range of expression for HPV type 16 and 18: high, medium, and negative. The same cell lines also demonstrate high homogenous, high heterogenous and negative expression of p16. Analyte controls are placed at one end of slide, allowing sample application on same slide for valid comparison.
The HPV/p16 Analyte Control cell microarray block contains three cell line cores that are 2 mm in diameter and between 3.0-3.5 mm in length. The cell microarray block may yield over 300 sections depending on thickness.
The HPV/p16 Analyte Control histology slides have three cell line cores providing a range of expression for HPV type 16 and 18: high, medium, and negative. The same cell lines also demonstrate high homogenous, high heterogenous and negative expression of p16. Analyte controls are placed at one end of slide, allowing sample application on same slide for valid comparison.
The HPV/p16 Analyte Control cell microarray block contains three cell line cores that are 2 mm in diameter and between 3.0-3.5 mm in length. The cell microarray block may yield over 300 sections depending on thickness.
제조 메모
Cell microarray blocks are fixed in 10% neutral buffered formalin and embedded in paraffin wax. Pre-cut unstained slides are prepared from 4 μm thick sections, mounted on positively charged slides, and dried at 37 °C overnight.
기타 정보
For certificates of analysis, contact info@histocyte.com.
HPV/p16 Analyte Control brochure is available from HistoCyte Laboratories.
HPV/p16 Analyte Control brochure is available from HistoCyte Laboratories.
시험 성적서(COA)