GE28-9924-74

HiScreen Capto Blue

Cytiva 28-9924-74, pack of 1 column

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151817
NACRES:
NA.56

포장

pack of 1 column

제조업체/상표

Cytiva 28-9924-74

파라미터

1.2 ml/min - 2.3 ml/min flow rate
44 psi

베드 크기

7.7 mm × 100 mm

베드 용적

4.7 mL

용량

~25 mg binding capacity(human serum albumin/ml medium)

저장 온도

2-8°C

일반 설명

HiScreen™ columns are part of the process development platform available from Cytiva. The columns are prepacked with a range of BioProcess chromatography media (resins) and designed for method optimization and parameter screening. HiScreen™ columns have small bed volumes (4.7 ml), reducing the cost of sample and buffer consumption. The media used in HiScreen™ columns are also available in other prepacked formats and as bulk packs, for all scales of work from development and pilot studies to routine production.

애플리케이션

HiScreen Capto Blue is prepacked with the base matrix Capto to which Cibacron Blue 3G is covalently bound via a hydrophilic spacer immobilized with a stable amine bond. Capto Blue is highly chemically stable and has a more rigid Agarose base matrix than Blue Sepharose 6 Fast Flow. This allows the use of faster flow rates and larger sample volumes, leading to higher throughput and improved process economy. The application area is the same as for Blue Sepharose Fast FLow (e.g., purification of albumin, enzymes including NAD+ and NADP+, coagulation factors, interferons, and related Proteins). The main benefit of Capto Blue compared to Blue Sepharose 6 Fast FLow is its improved chemical stability provided with a new coupling chemistry involving a spacer arm. It tolerates repeated cleaning-in-place and sanitization at both high and Low pH as well as autoclaving. Also the leakage of Cibacron Blue is reduced as compared to Blue Sepharose 6 Fast Flow.

특징 및 장점

  • Prepacked with Capto Blue
  • Excellent for method optimization and parameter screening due to the 10 cm bed height
  • Easily connected in series to achieve 20 cm bed height
  • Small bed volume for fast results and minimal sample/buffer consumption
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same flow velocity

저장 및 안정성

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

분석 메모

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

기타 정보

The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

법적 정보

Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva
Sepharose is a trademark of Cytiva

픽토그램

Flame

신호어

Warning

유해 및 위험 성명서

Storage Class Code

3 - Flammable liquids


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

문서

This page shows how to convert between flow velocity and volumetric flow rate in affinity chromatography of antibodies.

프로토콜

This page shows how purify or remove albumin with Blue Sepharose and Capto Blue from Cytiva.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.