추천 제품
ligand
octyl
포장
pkg of 4.7 mL
제조업체/상표
Cytiva 28-9269-86
파라미터
1.5 bar (22 psi) (Over the Packed Bed During Operation)
22 psi
베드 크기
7.7 mm × 100 mm
베드 용적
4.7 mL
컬럼 I.D.
7.7 mm
기질
4% cross-linked agarose
입자 크기
45-165 μm
평균 직경
90 μm
cleaning
2-14
working range
3-13
적합성
suitable for bioprocess medium
관련 카테고리
일반 설명
HiScreen Octyl FF columns are prepacked with Octyl Sepharose 4 Fast Flow hydrophobic interaction chromatography (HIC) resins. The columns are an excellent choice for method optimization and parameter screening.
The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.
If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.
Media prepacked in HiScreen HIC columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.
The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.
If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.
Media prepacked in HiScreen HIC columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.
특징 및 장점
- Octyl Sepharose 4 Fast Flow is a well-established, standard aliphatic HIC medium for capture and intermediate purification.
- Prepacked, ready-to-use columns for convenient process development optimization.
- 1NA cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
- Easily connected in series to achieve 2NA cm bed height.
- Small bed volume gives fast results and minimal sample/buffer consumption.
- Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity.
저장 및 안정성
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol or 0.01 M NaOH)
Store at 4 to 30 °C (20% Ethanol)
분석 메모
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
법적 정보