추천 제품
ligand
alkali-stabilized protein A-derived (E. coli)
포장
pkg of 1 ea
제조업체/상표
Cytiva 28-9269-77
저장 조건
(20% Ehtanol)
(20% Ethanol)
파라미터
44 psi
베드 크기
7.7 mm × 100 mm
베드 용적
4.7 mL
컬럼 I.D.
7.7 mm
Matrix
highly cross-linked agarose
평균 부품 크기
85 μm (d₅₀v is the median particle size of the cumulative volume distribution)
cleaning
2-13.7
작동 범위
3-12
용량
≥30 mg binding capacity (humanlgG/ml at 2.4 min residence time)
적합성
suitable for bioprocess medium
저장 온도
2-8°C
일반 설명
Determined at 10% breakthrough by frontal analysis at a mobile phase velocity of 500 cm/h in a column with a bed height of 20 cm.
HiScreen™ MabSelect™ SuRe™ is prepacked with MabSelect™ SuRe™ and is part of the process development platform available from Cytiva. The columns are an excellent choice for method optimization and parameter screening for capture of monoclonal antibodies (MAbs).
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.
애플리케이션
Lab Purification using the MabSelect™ SuRe™ Protein A tag for capture of antibodies.
특징 및 장점
- The novel, alkali-tolerant recombinant protein A ligand of MabSelect™ Sure allows cleaning-in-place (CIP).
- Prepacked, ready-to-use columns for convenient process development.
- 10 cm bed height of HiScreen™ columns is designed to allow method optimization and parameter screening.
저장 및 안정성
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
분석 메모
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
법적 정보
Free MabSelect SuRe Ligand
"MabSelect SuRe Ligand Restricted License" and "Cys-rProtein A Ligand Restricted License" are protected by the following patents and equivalent patents and patent applications in other countries: US 6,399,750 and EP 1123389. A free, non-transferable limited license to use this product for internal analytical purposes only accompanies the purchase of the product from a Cytiva company and its licensed distributors. Any other use will require a separate license from a Cytiva company.
"MabSelect SuRe Ligand Restricted License" and "Cys-rProtein A Ligand Restricted License" are protected by the following patents and equivalent patents and patent applications in other countries: US 6,399,750 and EP 1123389. A free, non-transferable limited license to use this product for internal analytical purposes only accompanies the purchase of the product from a Cytiva company and its licensed distributors. Any other use will require a separate license from a Cytiva company.
HiScreen is a trademark of Cytiva
MabSelect is a trademark of Cytiva
SuRe is a trademark of Cytiva
신호어
Warning
유해 및 위험 성명서
Storage Class Code
3 - Flammable liquids
가장 최신 버전 중 하나를 선택하세요:
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.