추천 제품
Grade
for GPC
유통기한
limited shelf life, expiry date on the label
기술
gel permeation chromatography (GPC): suitable
형식
neat
저장 온도
2-8°C
애플리케이션
- PMMA molecular weight calibration in medical device manufacturing: High molecular weight PMMA is used in the stereolithography fabrication of medical devices, ensuring precise control over polymer properties for innovative therapeutic applications (Drizdal et al., 2012).
- Biopolymer size characterization for protein analysis: PMMA standards are essential in the development of miniaturized gel electrophoresis devices, facilitating the analysis of proteins which is pivotal in pharmaceutical research and diagnostic applications (Demianova et al., 2008).
포장
1 set contains 30 vials for 10 complete calibrations
성분
ReadyCal Standards are polymer cocktails pre-weighed into autosampler vials for the convenient calibration of GPC/SEC/GFC systems.
This kit contains 10 sets of 3 color-coded vials, each containing four polymethyl methacrylates of different molar masses. Molar masses range from ~800 to ~2,200,000 Da and are carefully selected so that polymer traces are baseline separated.
Each kit contains sufficient material for at least 10 calibrations and includes an instruction manual and calibration curve with measurement conditions.
Suitable for calibrations in THF, toluene, HFIP, acetone, DMF, DMAc, DMSO, chloroform and NMP.
This kit contains 10 sets of 3 color-coded vials, each containing four polymethyl methacrylates of different molar masses. Molar masses range from ~800 to ~2,200,000 Da and are carefully selected so that polymer traces are baseline separated.
Each kit contains sufficient material for at least 10 calibrations and includes an instruction manual and calibration curve with measurement conditions.
Suitable for calibrations in THF, toluene, HFIP, acetone, DMF, DMAc, DMSO, chloroform and NMP.
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
Choose from one of the most recent versions:
이미 열람한 고객
mSphere, 5(5) (2020-09-11)
The major surface lipophosphoglycan (LPG) of Leishmania parasites is critical to vector competence in restrictive sand fly vectors in mediating Leishmania attachment to the midgut epithelium, considered essential to parasite survival and development. However, the relevance of LPG for sand