추천 제품
Grade
reference material
Quality Level
vapor pressure
1.33 (1.00 mmHg) at 865 °C hPa
분석
>99.5%
품질
certified by BAM
기술
titration: suitable
pH
7
mp
801 °C (lit.)
solubility
water: soluble (358 g/l at 20 °C (68 °F))
형식
neat
SMILES string
[Na+].[Cl-]
InChI
1S/ClH.Na/h1H;/q;+1/p-1
InChI key
FAPWRFPIFSIZLT-UHFFFAOYSA-M
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Sodium chloride (NaCl) is a volumetric standard manufactured under rigorous conditions and analyzed with the highest possible precision. The content of the standard is measured by volumetric argentometric titration and the measurement can be traced back to NIST SRM. Its certified value and uncertainty measurement are in accordance with ISO Guide 35.
애플리케이션
It finds its use as a certified reference material (CRM) for the standardization of volumetric solutions in argentometric titrations.
특징 및 장점
- Available as a solid in a contamination-proof glass bottle to ensure its stability for the entire shelf life until opened.
- High-purity material traceable to SRMs from NIST
- High-quality offering accurate titer determinations
- Accompanied by a certificate of analysis (CoA)
분석 메모
Exact concentration, expiry date, traceability and detailed information on certification can be found on the certificate and certification report, included in each package. Content and expiry date on label.
Storage Class Code
11 - Combustible Solids
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
Choose from one of the most recent versions:
이미 열람한 고객
Determination of chloride in infant formula and adult/pediatric nutritional formula by automated potentiometry: Single-Laboratory Validation, First Action 2015.08.
Journal of AOAC (Association of Official Analytical Chemists) International, 98, 1390-1394 (2015)
JAMA, 311(1), 45-52 (2013-11-19)
Hospital cooling improves outcome after cardiac arrest, but prehospital cooling immediately after return of spontaneous circulation may result in better outcomes. To determine whether prehospital cooling improves outcomes after resuscitation from cardiac arrest in patients with ventricular fibrillation (VF) and
Genome biology, 15(8), 426-426 (2014-08-27)
Genomic analyses of hundreds of prostate tumors have defined a diverse landscape of mutations and genome rearrangements, but the transcriptomic effect of this complexity is less well understood, particularly at the individual tumor level. We selected a cohort of 25
Nature communications, 6, 6337-6337 (2015-02-27)
Pore-forming toxins (PFT) are water-soluble proteins that possess the remarkable ability to self-assemble on the membrane of target cells, where they form pores causing cell damage. Here, we elucidate the mechanism of action of the haemolytic protein fragaceatoxin C (FraC)
Journal of clinical microbiology, 52(7), 2359-2364 (2014-04-25)
Multidrug-resistant Acinetobacter baumannii isolates, particularly those that produce carbapenemases, are increasingly reported worldwide. The biochemically based Carba NP test, extensively validated for the detection of carbapenemase producers among Enterobacteriaceae and Pseudomonas spp., has been modified to detect carbapenemase production in
문서
Explore the tests integral to the instrument qualification process for ion chromatography instruments. Learn about the effectiveness of a pre-packaged IQ/OQ/PQ kit, featuring six certified bromide standard solutions for comprehensive IC instrument qualification tests.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..