콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

01829

Supelco

Extractables and Leachables Screening Standard for GC

certified reference material, TraceCERT®, 14 components in tert-Butyl methyl ether, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41116107
NACRES:
NA.24

Grade

certified reference material

Quality Level

grade

TraceCERT®

유통기한

limited shelf life, expiry date on the label

제조업체/상표

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

농도

50 mg/L each component (nominal concentration)

응용 분야

pharmaceutical

형식

multi-component solution

저장 온도

−20°C

일반 설명

This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to the SI through a primary reference material from an NMI, e.g. NIST, NRC or NMIJ.
Certified content incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com.

Check out our complete range of extractables and leachables certified reference mixes

애플리케이션

Extractables Study with GC/MS - Extractables Studies of Single-Use Equipment article from >AnalytixReporter issue 8

제조 메모

For the preparation of this CRM only materials of highest purity were used.

법적 정보

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

분석물

설명

    Octadecyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate
    ε-Caprolactam
    2-Mercaptobenzothiazole
    Bisphenol A
    3,5-Di-tert-butyl-4-hydroxytoluene
    1,3-Di-tert-butylbenzene
    Oleamide
    Bis(2-ethylhexyl) phthalate
    Stearic acid
    cis-13-Docosenoamide
    Tris(2,4-di-tert-butylphenyl)phosphate
    2,4-Di-tert-butylphenol
    2,6-Di-tert-butylphenol
    Palmitic acid
    모두 보기 (14)

픽토그램

FlameExclamation mark

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Flam. Liq. 2 - Skin Irrit. 2

Storage Class Code

3 - Flammable liquids

WGK

WGK 1

Flash Point (°F)

-18.4 °F - closed cup

Flash Point (°C)

-28 °C - closed cup


Choose from one of the most recent versions:

시험 성적서(COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

문서

Identification and quantification of the most common extractables originating from single-use equipment by GC/MS and an Extractables and Leachables Screening Standard.

Ascentis® C18 column facilitates LC-UV/MS analysis of extractables from single-use systems, ensuring reliable identification and quantification.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.