추천 제품
material
PVDF
polyester support
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
silicone outer O-ring
silicone-coated EPDM rubber lead O-ring
Quality Level
규정 준수
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
무균
non-sterile
멸균 적합성
gamma compatible
제품 라인
Opticap® XL 4
특징
gamma compatible
hydrophilic
제조업체/상표
Opticap®
파라미터
≤5.7 mL/min air diffusion at 3.9 bar (56 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.8 bar max. differential pressure (40 psid) at 25 °C (Reverse; intermittent)
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
기술
sterile filtration: suitable
길이
7.7 in.
너비
3.3 in.
카트리지 공칭 길이
4 in. (10 cm)
직경
6.1 cm (2.4 in.)
여과 면적
0.18 m2
입구 연결 직경
1.5 in.
출구 연결 직경
1.5 in.
불순물
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
기질
Durapore®
공극 크기
0.1 μm
입력
sample type liquid
버블 포인트(bubble point)
≥4830 mbar (70 psig), air with water at 23 °C
피팅
1/4 in. drain/vent hose barb (with double O-ring Seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
일반 설명
포장
기타 정보
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
제조 메모
3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
분석 메모
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 ºC.