콘텐츠로 건너뛰기
Merck

다음으로 건너뛰기

HFSAMPLE02

Hi-Flow Plus Variety Sample Pack

backing thickness 2 mil, size 30.5 cm × 25 cm, pack of 10 sheets (2 sheets of each speed)

동의어(들):

HF, Hi-Flow, Hi-Flow Plus 2mil Sample pack, immunoassay membrane, lateral flow membrane, nitrocellulose membrane

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택

보기 변경
여러분께/SKU재고 정보가격 (VAT 별도)

제품정보 (DICE 배송 시 비용 별도)

UNSPSC Code:
40161507
NACRES:
NA.28
eCl@ss:
32031602
가격 및 재고 정보를 현재 이용할 수 없음
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의


packaging

pack of 10 sheets (2 sheets of each speed)

Quality Segment

backing thickness

2 mil

size

30.5 cm × 25 cm

General description

Hi-Flow Plus membranes are designed and optimised for use in rapid diagnostic lateral flow tests that require superior consistency and performance. Lateral flow tests faciliate quick and convenient detection / quantification of analytes such as antibodies and antigens present in biological samples, including blood, saliva, and urine. Hi-Flow™ Plus membranes are ideally suited for such applications. Available in a variety of capillary flow times and backing options, choosing Hi-Flow™ Plus membranes can improve assay performance and offer flexibility to meet a wide range of assay design requirements. This convenient variety sample pack contains 10 sheets; 2 sheets each of Hi-Flow™ Plus 75, 90, 120, 135, 180 membrane on 2 mil backing.

Application

  • Hi-Flow Plus membrane is a critical raw material suitable for use in a broad range of Lateral Flow test applications, including Infectious Disease testing (COVID-19, HIV, Influenza, Malaria, STDs etc.), as well as in women’s health, biomarker detection, drugs of abuse testing, drug development, environmental testing, agricultural applications, food safety, product quality testing and animal health.
  • Hi-Flow Plus membranes are suitable for use with all lateral flow test techniques including competitive, sandwich, and multiplex detection assays.
  • They are optimised for use in both qualitative and quantitative test types and pair well with lateral flow detector particles including colloidal gold nanoparticles, dyed/ fluorescent microspheres etc.
  • Hi-Flow Plus membranes are suitable for use in lateral flow tests designed to detect analytes present in a broad range of samples matrices including, blood, saliva, urine, nasopharyngeal swabs, sweat and others.

Features and Benefits

FEATURES:
  • Consistent Flow & Surface Chemistry, Robust manufacturing process
  • Proprietary Surface Chemistry Optimised for Lateral Flow Applications
  • High Quality Level: MQ400
  • Trusted Partner and Brand with Decades of membrane manufacturing experience
  • High production capacity, high stock levels, multiple manufacturing lines
  • Convenient samples packs available in several formats
  • Manufacturing scale quantities available to purchase online with immediate shipping.
We offer a complete solution; along with Hi-Flow Plus membranes we offer raw materials across the entire lateral flow workflow as well as assay development services (include link to Lateral Flow Assay Development Services (sigmaaldrich.com))BENEFITS:
  • Consistent capillary flow time and membrane thickness
  • Superior surface morphology allows for consistent and even flow distribution of reagents across the membrane surface
  • Sharp, intense, and uniform test and control line formation
  • Excellent intra-lot and inter-lot consistency.
  • Better Assay sensitivity
  • Excellent reproducibility
  • Improved lateral flow test manufacturing yields.
  • Quick Delivery and Lead time.
  • No supply disruption
  • Excellent Technical support

Packaging

2 sheets each of Hi-Flow Plus 75, 90, 120, 135, 180 membranes, 2 mil backed

Legal Information

Hi-Flow is a trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?


pictograms

Flame

signalword

Danger

저장 등급

4.1B - Flammable solid hazardous materials

Hazard Classifications

Aquatic Chronic 3 - ED ENV 1 - Flam. Sol. 1



시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문



질문

  1. Are these backing card used for assembly of all pads ?

    1 답변
    1. Backed membranes cast onto a nonporous, polyester film offer two advantages. First, these membranes are easier to handle. The film provides a high level of mechanical strength. Secondly, the film acts as a barrier to chemical contamination from adhesives that are used to mount the membrane on cards during test strip manufacture.

      The most common backings are 2-mil and 4-mil polyester films. Membranes on these backings perform similarly. Please be aware that film thickness is dictated by constraints of the test strip manufacturing process and the tolerances of the intended space in the housing. Unbacked membranes, in comparison, are extremely fragile and can be very difficult to work with during test strip assembly.

      도움이 되었습니까?