추천 제품
Quality Level
종 반응성
human
제조업체/상표
Milliplex®
assay range
accuracy: 92%
(Endostatin)
accuracy: 95%
(ucMGP)
accuracy: 97%
(DPP4/sCD26)
sensitivity: 0.007 ng/mL
(MinDC+2SD; Endostatin)
sensitivity: 0.014 ng/mL
(MinDC+2SD; pGRN)
sensitivity: 0.015 ng/mL
(MinDC+2SD; LRG1)
sensitivity: 0.016 ng/mL
(MinDC+2SD; MCAM)
sensitivity: 0.016 ng/mL
(MinDC+2SD; sCD14)
sensitivity: 0.041 ng/mL
(MinDC+2SD; DPP4)
sensitivity: 0.052 ng/mL
(MinDC+2SD; ucMGP)
standard curve range: 0.002-10 ng/mL
(Endostatin)
standard curve range: 0.01-40 ng/mL
(sCD14)
standard curve range: 0.024-100 ng/mL
(LRG1)
standard curve range: 0.024-100 ng/mL
(MCAM)
standard curve range: 0.024-100 ng/mL
(pGRN)
standard curve range: 0.049-200 ng/mL
(DPP4/sCD26)
standard curve range: 0.049-200 ng/mL
(ucMGP)
inter-assay cv: <10%
intra-assay cv: <5%
(DPP4/sCD26)
inter-assay cv: <10%
intra-assay cv: <5%
(Endostatin)
inter-assay cv: <10%
intra-assay cv: <5%
(LRG1)
inter-assay cv: <10%
intra-assay cv: <5%
(MCAM)
inter-assay cv: <10%
intra-assay cv: <5%
(pGRN)
inter-assay cv: <20%
intra-assay cv: <10%
(ucMGP)
inter-assay cv: <20%
intra-assay cv: <5%
(sCD14)
기술
multiplexing: suitable
검출 방법
fluorometric (Luminex xMAP)
배송 상태
ambient
일반 설명
The MILLIPLEX® Human Cardiovascular Disease (CVD) Panel 6 is a 7-plex kit may be used to simultaneously quantify any or all the following analytes in human serum, plasma, and tissue culture samples: Soluble Cluster of Differentiation 14 (sCD14), Dipeptidyl Peptidase-4 (DPP4/DPPIV) / Soluble Cluster of Differentiation 26 (sCD26), Endostatin / Collagen Alpha-1 (XVIII) (COL181A), Progranulin (pGRN) / Proepithelin (PEPI) / PC Cell-derived Growth Factor (PCDGF) / Acrogranin / Paragranulin, Leucine-rich Alpha-2-Glycoprotein 1 (LRG1), Melanoma Cell Adhesion Molecule (MCAM) / Soluble Cluster of Differentiation 146 (sCD146) / Cell Surface Glycoprotein MUC18, Uncarboxylated Matrix Gamma-Carboxyglutamate (Gla) Protein (ucMGP). This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Cardiovascular
특이성
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
애플리케이션
- Analytes: Monocyte Differentiation Antigen (CD14/sCD14), Dipeptidyl Peptidase-4 (DPP4/sCD26), Endostatin, Leucine-rich α-2-glycoprotein 1 (LRG1), Cell Surface Glycoprotein (MCAM/ MUC18/sCD146), Progranulin (pGRN), Uncarboxylated Matrix Gla Protein (ucMGP)
- Recommended Sample Type:
- Human serum, plasma, cell/tissue culture supernatants and lysates
- Recommended Sample Dilution: 25 μL per well of 1:500 diluted serum or plasma; cell/tissue culture supernatants or lysates may be used undiluted ore or diluted in appropriate control medium
- Assay Run Time: Overnight (16-18 hours)at 2-8°C will yield optimal sensitivity.2- A 2 hour incubation at room temperature (20-25°C) may also be used.
- Research Category: Cardiovascular Disease
- Research Subcategory: Metabolic Disorders
특징 및 장점
포장
저장 및 안정성
기타 정보
법적 정보
면책조항
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
표적 기관
Respiratory Tract
Storage Class Code
10 - Combustible liquids
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
관련 콘텐츠
Multiplex CVD panels like MILLIPLEX® assays enhance biomarker discovery for cardiovascular disease research.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.