콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

1.50798

Supelco

Purospher® RP-18 endcapped (5 µm) HPLC Columns

L × I.D. 125 mm x 3 mm LiChroCART® HPLC cartridge, manuCART holder required for use

동의어(들):

Purospher® RP-18 endcapped (5 µm) LiChroCART® 125-3

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115709
NACRES:
SB.52

product name

Purospher® RP-18 endcapped (5 µm), L × I.D. 125 mm x 3 mm LiChroCART® HPLC cartridge, manuCART holder required for use

material

stainless steel column

Quality Level

Agency

suitable for USP L1

제품 라인

Purospher®

특징

endcapped

포장

1 ea of

라벨링 범위

18% Carbon loading

파라미터

250 bar pressure
65 °C max. temp.

기술

HPLC: suitable
LC/MS: suitable
mass spectrometry (MS): suitable (High)

컬럼 길이 × I.D.

12.5 cm × 3 mm

표면적

350 m2/g

기질

fully porous particle

기질 활성군

C18 bonding phase

입자 크기

5 μm

공극 크기

120 Å pore size

작동 pH

2-7.5

분리 기술

reversed phase

저장 온도

no temp limit

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

HPLC cartridge
Purospher® RP-18 endcapped is a versatile high-purity HPLC column producing excellent peak shapes. The excellent balance of Purospher<TMSYMBOL></TMSYMBOL> RP-18 endcapped in the sum of its chromatographic properties is the key to better separations of complex samples with simpler, neutral eluents. The good chemical stability of Purospher<TMSYMBOL></TMSYMBOL> RP-18 endcapped enables the use of mobile phase conditions at pH 8 for a long period of time. The connection to the HPLC system is being accomplished by use of the manu-CART NT cartrige holder (1.51486).

애플리케이션


  • Determination of nifedipine in serum of women in preterm labor by high-performance liquid chromatography with diode array detection.: This study utilized Purospher® RP-18 endcapped (5 µm) columns in the HPLC analysis of nifedipine levels in serum samples from women in preterm labor. The research demonstrated the effectiveness of the Purospher® RP-18 columns in achieving high resolution and sensitivity, making it a valuable tool for bioanalytical applications in clinical chemistry (Kowalczuk et al., 2006).

분석 메모

Pressure: ≤ 60 bar
Theoretical Plates (N/m) (Anthracene): ≥ 65000
Symmetry (Anthracene): 0.8 - 1.4
Capacity factor (Anthracene): 4.5 - 6.5

법적 정보

LICHROCART is a registered trademark of Merck KGaA, Darmstadt, Germany
MANUCART is a trademark of Merck KGaA, Darmstadt, Germany
Purospher is a registered trademark of Merck KGaA, Darmstadt, Germany

시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..