콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

1.50646

Supelco

Purospher® STAR RP-18 endcapped (2 µm) HPLC Columns

L × I.D. 50 mm x 2.1 mm Hibar® HR UHPLC Column

동의어(들):

Purospher®STAR RP-18 endcapped (2µm) Hibar® HR 50-2.1

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115709
NACRES:
SB.52

product name

Purospher® STAR RP-18 endcapped (2 µm), L × I.D. 50 mm x 2.1 mm Hibar® HR UHPLC column

material

stainless steel column

Quality Level

Agency

suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for EPA 1633
suitable for EPA 38407-42
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA 8327
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
suitable for ISO 25101
suitable for ISO/CEN 15968-2010
suitable for USP L1

제품 라인

Purospher®

특징

endcapped

포장

1 ea of

라벨링 범위

17% Carbon loading

파라미터

1000 bar pressure
65 °C max. temp.

기술

LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)

컬럼 길이 × I.D.

5 cm × 2.1 mm

표면적

330 m2/g

기질

fully porous particle

기질 활성군

C18 bonding phase

입자 크기

2 μm

공극 크기

120 Å pore size

operating pH range

1.5-10.5

분리 기술

reversed phase
supercritical fluid (SFC)

저장 온도

no temp limit

유사한 제품을 찾으십니까? 방문 제품 비교 안내

관련 카테고리

일반 설명

Purospher® STAR RP-18 endcapped, 2 µm UHPLC columns are designed for use in UHPLC Applications and instruments providing full UHPLC resolution and highest separation efficiency′s at maximum pressure of 1000 bar.Purospher® STAR RP-18 endcapped, 2 µm UHPLC columns allow the separation of basic, neutral, and metal chelating compounds with simple mobile phases and excellent peak symmetry. They are based on ultra-pure fully porous silica particles (Type B). These columns offer an outstanding stability from pH 1.5 to 10.5 over a wide temperature range, and suitability for up to 100% aqueous mobile phases. Plus, they demonstrate best all-round retention characteristics, as proven by the Tanaka test. Purospher® STAR RP-18 endcapped, 2 µm Hibar® HR 50-2.1 is a ready to use UHPLC column suitable for connection to any UHPLC system providing a pressure stability of 1000 bar.The column dimension of 50 mm length x 2.1 mm I.D. is the optimal choice for high throughput UHPLC separation of complex samples allowing significant solvent savings and improved sensitivity.Learn more about Purospher® STAR HPLC and UHPLC ColumnsLearn more about the Supelco HPLC Column portfolio and Method development:Brochure: HPLC and UHPLC Column Selection GuideBrochure: A Practical Guide to HPLC - Method Development Guide

애플리케이션

Intended to be used in the separation of aflatoxins, aldehydes, alkaloids, antibiotics, catecholamines, explosives, oligonucleotides, esters, fat soluble vitamins, lipids, fatty acids, flavonoids, ketones, nitrosamines, nucleosides, PAHs, PCBs, peptides, pesticides, phenols, phthalates, preservatives, steroids, metabolized steroids, sulfonamides, sweeteners, and water soluble vitamins.

특징 및 장점

  • Ultra-pure silica (99.999%) for excellent peak symmetry
  • High separation efficiency
  • Reproducible results from run-to-run and batch-to-batch
  • Best all-round performance according to Tanaka
  • Outstanding pH stability from pH 1.5 to 10.5
  • No phase collapse when using highly aqueous mobile phases
  • Good suitability for LC-MS applications

분석 메모

Pressure: ≤ 140 bar
Theoretical Plates (N/m) (1,2-Benzanthracene): ≥ 170000
Symmetry (1,2-Benzanthracene): 0.8 - 1.4
Capacity factor (1,2-Benzanthracene): 8.5 - 11.5

법적 정보

ASTM is a registered trademark of American Society for Testing and Materials
Hibar is a registered trademark of Merck KGaA, Darmstadt, Germany
Purospher is a registered trademark of Merck KGaA, Darmstadt, Germany

시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

문서

This article presents an LC-MS/MS method for the determination of tramadol in urine samples using reversed-phase LC-MS/MS aided by isotope internal standards.

This study assesses the suitability of ultrapure water from a Milli-Q® water system for sensitive LC-MS analyses of hormones.

Discover the Tanaka Test, a key protocol for evaluating the performance and selectivity of stationary phases in Reversed Phase HPLC separations.

Milli-Q® 초순수 시스템은 실험실 수돗물 내 호르몬을 포함하여 유기 오염물질이 없는 정제수를 제공하므로 가장 민감한 LC-MS/MS 분석에 적합합니다.

모두 보기

관련 콘텐츠

저분자는 일반적으로 900달톤 이하의 분자량을 가지는 이온과 화합물입니다. 이러한 화합물은 주로 실리카 입자 또는 광범위한 컬럼 화학물(변경)의 단일 고정상을 사용하여 HPLC, UHPLC, LC-MS로 효과적으로 분리되고 분석될 수 있습니다.

Small molecules are ions and compounds of molecular weight typically less than 900 daltons. These compounds can be effectively separated and analyzed by HPLC, UHPLC and LC-MS using mainly silica particles or monolithic stationary phases with a broad range of column chemistries (modifications).

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.