추천 제품
material
glass support
silica gel 60 matrix
Quality Level
특징
binder Organic Polymer
fluorescent indicator: no
포장
pkg of 25 plates
기술
thin layer chromatography (TLC): suitable
레이어 두께
250 μm
플레이트 길이 × 너비
20 cm × 20 cm
입자 크기
10-12 μm
공극 크기
60 Å medium pore diameter
저장 온도
2-30°C
일반 설명
25 Glass plates 20 x 20 cm
Our classical silica TLC plates are based on a combination of our proven silica gel 60 and the addition of a unique polymeric binder resulting in a very adherent and hard surface that will not crack or blister and even allow writing with a pensil on the surface without risk to damage the layer.
애플리케이션
- Pressurized planar electrochromatography of DNS amino acids derivatives in silica gel and silanized silica gel systems with formic acid addition to the water mobile phase: This study explores the separation selectivity of dansyl (DNS) derivatives of amino acids using pressurized planar electrochromatography (PPEC) on Silica gel 60 TLC plates. The research demonstrates significant differences in separation selectivity between high-performance thin-layer chromatography (HPTLC) and PPEC systems, highlighting the electrophoretic effects in the PPEC system (Chomicki and Dzido, 2021).
- Thin-layer chromatography of DNS amino acids derivatives in systems with silica gel and silanized silica gel plates: This article presents investigations into the separation selectivity of DNS derivatives of amino acids on Silica gel 60 TLC plates. The study shows the impact of varying concentrations of acetonitrile in the mobile phase on the separation efficiency, providing valuable insights for optimizing analytical techniques in biochemical research (Chomicki and Dzido, 2022).
- Determination of β-blocking receptor drugs in silica gel TLC systems with the mobile phase containing surfactant: This research examines the retention and separation of β-blocking drugs on Silica gel 60 TLC plates using mobile phases with surfactants. The study assesses the effect of surfactant concentration on zone shape properties and provides a quantitative analysis of selected solutes, emphasizing the method′s environmental friendliness due to low propanol use (Traczuk and Polak, 2022).
결합
Replaces: 5721-7; 5721
분석 메모
Specific surface area (according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 9.7 - 11.7 µm
Layer thickness: 210 - 270 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testing:
colour test
hRf-values
- bleu vif organol, colour test, lipophile:
11 - 25
- Ceres Black G, colour test, lipophile: 34 - 48
- ceres Violet brn, colour test, lipophile: 52 - 67
separation number (colourtest, lipophile): ≥ 10.5
Typical value determined on a conditioned plate
Eluent: toluene (45% rel. humidity)
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 9.7 - 11.7 µm
Layer thickness: 210 - 270 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testing:
colour test
hRf-values
- bleu vif organol, colour test, lipophile:
11 - 25
- Ceres Black G, colour test, lipophile: 34 - 48
- ceres Violet brn, colour test, lipophile: 52 - 67
separation number (colourtest, lipophile): ≥ 10.5
Typical value determined on a conditioned plate
Eluent: toluene (45% rel. humidity)
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
문서
Thin Layer Chromatography Troubleshooting: This article details TLC tips and tricks that one must consider while performing different steps of the technique.
HPTLC plates provide superior separation, speed, and sensitivity, making them ideal for advanced qualitative and quantitative analysis.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.