material
aluminum support
cellulose matrix
Quality Level
특징
binder Organic Polymer
fluorescent indicator: no
포장
pkg of 25 sheets
기술
thin layer chromatography (TLC): suitable
레이어 두께
70-110 μm
시트 길이 × 너비
20 cm × 20 cm
저장 온도
2-30°C
일반 설명
25 Aluminium sheets 20 x 20 cm
Our cellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid derivatives. We offer cellulose plates in two grades: TLC for conventional and HPTLC for demanding, high-performance separations.
애플리케이션
- Simple and sensitive determination of sulfites in Chinese herbal teas by ultrahigh-performance liquid chromatography tandem mass spectrometry: This study highlights the utilization of HILIC technology for the sensitive analysis of sulfites in herbal teas, demonstrating the versatility of SeQuant® ZIC-HILIC™ columns in maintaining the stability and enhancing the sensitivity of such measurements (Yang et al., 2022).
- Development and validation of LC-MS/MS methods to measure tobramycin and lincomycin in plasma, microdialysis fluid and urine: The research applies HILIC methods to effectively measure antibiotics in various biological fluids, providing an example of the column′s applicability in pharmacokinetic research studies (Pandey et al., 2020).
- Application of Hydrophilic Interaction Liquid Chromatography for the Quantification of Flavonoids in Genista tinctoria Extract: Demonstrates the use of HILIC for the effective separation and quantification of flavonoids, showcasing the column′s efficiency in handling complex herbal matrices (Sentkowska et al., 2016).
- HPLC-UV method development for fentanyl determination in rat plasma and its application to elucidate pharmacokinetic behavior after i.p. administration to rats: This study underlines the adaptability of SeQuant® ZIC-HILIC™ in developing methods for the forensic and pharmacological analysis of potent opioids in biological samples (Almousa et al., 2011).
- Hydrophilic interaction liquid chromatography/positive ion electrospray ionization mass spectrometry method for the quantification of perindopril and its main metabolite in human plasma: Highlights the application of HILIC in tandem with mass spectrometry for the analysis of drugs and their metabolites, emphasizing the column′s role in enhancing detection sensitivities (Georgakakou et al., 2010).
결합
Replaces: 5552-7; 5552
분석 메모
Layer thickness: 70 - 110 µm
Deviation of layer thickness per plate: ≤ 30 µm
Aminoacid test
hRf-values
- L-serine, amino acid test:
20 - 30
- L-threonine, amino acid test: 29 - 36
- L-alanine, amino acid test: 30 - 40
- L-methionine, amino acid test: 49 - 60
- L-phenylalanine, amino acid test: 59 - 70
- L-leucine, amino acid test: 66 - 76
Typical value determined on a sheet
Eluent: 1-Butanol/ acetone/ acetic acid/ water (35/35/7/23 v/v/v/v) twice developed
Deviation of layer thickness per plate: ≤ 30 µm
Aminoacid test
hRf-values
- L-serine, amino acid test:
20 - 30
- L-threonine, amino acid test: 29 - 36
- L-alanine, amino acid test: 30 - 40
- L-methionine, amino acid test: 49 - 60
- L-phenylalanine, amino acid test: 59 - 70
- L-leucine, amino acid test: 66 - 76
Typical value determined on a sheet
Eluent: 1-Butanol/ acetone/ acetic acid/ water (35/35/7/23 v/v/v/v) twice developed
법적 정보
SeQuant is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC-HILIC is a trademark of Merck KGaA, Darmstadt, Germany
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.