1.00595

Supelco

Chlorine Test, photometric

photometric, 0.030-6.00 mg/L (Cl2), Spectroquant®

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41116116
NACRES:
NA.24

product name

Chlorine Cell Test, photometric, 0.030-6.00 mg/L (Cl2), Spectroquant®

제품 라인

Spectroquant®

Quality Level

사용

sufficient for 200 tests (free chlorine)

특정 분석물질

chlorine

측정 범위

0.030-6.00 mg/L (Cl2)

기술

photometry: suitable

호환성

for use with Spectroquant® Move 100
for use with Spectroquant® Nova 60 A
for use with Spectroquant® Prove 100
for use with Spectroquant® Prove 300
for use with Spectroquant® Prove 600

검출 방법

photometric (DPD)

저장 온도

15-25°C

일반 설명

(free chlorine) Method: photometric, DPD 0.03 - 6.00 mg/l Cl₂ Spectroquant®
This Spectroquant® Chlorine test allows the accurate quantification of chlorine in various waters. Chlorinated disinfectants are still in common use all over the world, their major applications being in the chlorination of drinking water and swimming pools. In weakly acidic solution free chlorine reacts with dipropyl-p-phenylenediamine (DPD) to form a red-violet dye that is determined photometrically.
The method is analogous to EPA 330.5, APHA 4500-Cl2 G, and DIN EN ISO 7393-2.
All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
The Spectroquant® Cell Tests come with prefilled 16 mm round cells as well as all the required reagents to perform the analysis according to the procedure described in the accompanying instruction leaflet.

애플리케이션


  • Sustainable lindane waste remediation: Surfactant-driven residual DNAPL extraction and oxidation in a real landfill (LIFE SURFING).: This study uses a chlorine cell test to assess the effectiveness of surfactant-driven extraction and oxidation processes for the remediation of lindane waste in a landfill, highlighting innovative environmental cleanup methods (Fernández et al., 2024).

  • Disinfectant-induced ammonia oxidation disruption in microbial N-cycling process in aquatic ecosystem after the COVID-19 outbreak.: Utilizes chlorine cell tests to study the impact of disinfectants on microbial nitrogen cycling in aquatic systems, providing critical insights into environmental effects of increased disinfectant use during the pandemic (Yang et al., 2024).


법적 정보

SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

픽토그램

Exclamation markHealth hazard

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Eye Irrit. 2 - Repr. 1B

Storage Class Code

6.1D - Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

프로토콜

유리 염소를 위한 AQA 표준 - 유리 chlorine용 표준용액 조제

DIN EN ISO 7393에 따른 유리 Chlorine용 표준용액 조제

Preparation of a standard solution for free Chlorine according to DIN EN ISO 7393

유리 Chlorine용 AQA 표준 - 유리 Chlorine용 표준용액 조제 - 유리 Chlorine용 저장용액 조제: 먼저 약 6 - 14% 활성 chlorine을 함유하는 sodium hypochlorite 용액을 이용하여 1:10 희석액을 조제합니다. 이를 위해 sodium hypochlorite 용액 10 ml를 피펫으로 보정 또는 적합성이 확인된 100 ml 정량 플라스크 안에 넣은 뒤 분석용 정제수를 표선까지 채웁니다.

관련 콘텐츠

AQA Standard for free chlorine - Preparation of a standard solution for free chlorine

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..