콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

P-085

Supelco

(±)-Propranolol-D7 (ring-D7) solution

100 μg/mL in methanol with 5% 1 M HCl, ampule of 1 mL, certified reference material, Cerilliant®

동의어(들):

Propranolol-d7 (ring-d7)

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C16H14D7NO2
CAS Number:
Molecular Weight:
266.39
UNSPSC 코드:
41116107
NACRES:
NA.24

Grade

certified reference material

형태

liquid

특징

Snap-N-Spike®/Snap-N-Shoot®

포장

ampule of 1 mL

제조업체/상표

Cerilliant®

농도

100 μg/mL in methanol with 5% 1 M HCl

기술

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

응용 분야

clinical testing

형식

single component solution

저장 온도

−20°C

InChI

1S/C16H21NO2/c1-12(2)17-10-14(18)11-19-16-9-5-7-13-6-3-4-8-15(13)16/h3-9,12,14,17-18H,10-11H2,1-2H3/i3D,4D,5D,6D,7D,8D,9D

InChI key

AQHHHDLHHXJYJD-MIBSYSDMSA-N

일반 설명

Propranolol is a sympatholytic, non-selective beta blocker used to treat hypertension, anxiety and panic. The drug is sold under numerous brand names such as Inderal®, Avlocardyl, Deralin, and Dociton. This internal standard is suitable for quantitation of propranolol levels in patient samples using LC/MS or GC/MS for applications in clinical toxicology, diagnostic testing, forensic analysis, pharmaceutical research and isotope dilution methods.

애플리케이션


  • Colorimetric analysis platform based on thin layer chromatography for monitoring gluten cross-contamination in food industry.: This research introduced a colorimetric analysis platform using thin-layer chromatography to monitor gluten cross-contamination in the food industry. Sigma-Aldrich TLC plates facilitated precise detection, enhancing food safety and quality control measures (Martinez-Aviño A et al., 2024).

  • Contaminant Spot Check and Removal Assay (ContamSPOT) for Mass Spectrometry Analysis.: This study developed the ContamSPOT assay, leveraging thin-layer chromatography for the spot check and removal of contaminants before mass spectrometry analysis. Using Sigma-Aldrich TLC plates, the method significantly improved the accuracy of mass spectrometry results in analytical chemistry applications (Smeriglio N et al., 2024).


법적 정보

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Inderal is a registered trademark of Cranford Pharmaceuticals, LLC
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

픽토그램

FlameSkull and crossbonesHealth hazard

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

표적 기관

Eyes,Central nervous system

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point (°F)

51.8 °F - closed cup

Flash Point (°C)

11 °C - closed cup


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..