추천 제품
분석
98%
형태
liquid
포함
100 ppm hydroquinone as inhibitor
refractive index
n20/D 1.428 (lit.)
bp
88-90 °C/24 mmHg (lit.)
density
0.888 g/mL at 25 °C (lit.)
SMILES string
CCCCCCOC(=O)C=C
InChI
1S/C9H16O2/c1-3-5-6-7-8-11-9(10)4-2/h4H,2-3,5-8H2,1H3
InChI key
LNMQRPPRQDGUDR-UHFFFAOYSA-N
일반 설명
Poly(hexyl acrylate-co-1,4-butanediol diacrylate-co-[2-(acryloyloxy)ethyl]trimethyl ammonium chloride) can be prepared by the photopolymeirzation of hexyl acrylate and several other components. These polyacrylate-based monolithics were designed to be used for capillary electrochromatography (CEC). Mutagenicity of this acrylate ester was evaluated by the Salmonella-microsome test.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1B - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
10 - Combustible liquids
WGK
WGK 2
Flash Point (°F)
154.4 °F - closed cup
Flash Point (°C)
68 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Non-mutagenicity of 27 aliphatic acrylate esters in the Salmonella-microsome test
Mutation Research. Genetic Toxicology and Environmental Mutagenesis, 137(2-3), 95-102 (1984)
ACS applied materials & interfaces, 9(37), 31488-31496 (2017-08-26)
Cochlear Implants (CIs) suffer from limited tonal resolution due, in large part, to spatial separation between stimulating electrode arrays and primary neural receptors. In this work, a combination of physical and chemical micropatterns, formed on acrylate polymers, are used to
Electrophoresis, 29(18), 3875-3886 (2008-10-14)
A polyacrylate-based monolithic column bearing cationic functionalities and designed for capillary electrochromatography (CEC) has been prepared via photopolymerization of a mixture of hexyl acrylate, butanediol diacrylate, 2-(acryloyloxy) ethyltrimethyl ammonium chloride (monomers), azobisisobutyronitrile (photoinitiator), acetonitrile, phosphate buffer, and ethanol (porogens). The
Talanta, 163, 17-23 (2016-11-26)
Analytical benefits related to application of copolymeric microspheres containing different number of carboxylic acid mers have been studied on example of acrylate copolymers. These structures can be used as a reagent in heterogeneous pH titration, benefiting from different number of
Soft matter, 15(26), 5193-5203 (2019-06-18)
The combination of precision control with wide tunability remains a challenge for the fabrication of porous nanomaterials suitable for studies of nanostructure-behavior relationships. Polymer micelle templates broadly enable porous materials, however micelle equilibration hampers independent pore and wall size control.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.