콘텐츠로 건너뛰기
Merck
모든 사진(3)

문서

335681

Sigma-Aldrich

Ethylene glycol dimethacrylate

98%, cross-linking reagent polymerization reactions, methacrylate, 90-110 ppm monomethyl ether hydroquinone as inhibitor

동의어(들):

Polyethylene glycol, 1,2-Ethanediol dimethacrylate, Ethylene dimethacrylate

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
CH2=C(CH3)COOCH2CH2OCOC(CH3)=CH2
CAS Number:
Molecular Weight:
198.22
Beilstein:
1776663
EC Number:
MDL number:
UNSPSC 코드:
12162002
PubChem Substance ID:
NACRES:
NA.23

product name

Ethylene glycol dimethacrylate, 98%, contains 90-110 ppm monomethyl ether hydroquinone as inhibitor

vapor density

>1 (vs air)

Quality Level

vapor pressure

<0.1 mmHg ( 21.1 °C)

분석

98%

형태

liquid

포함

90-110 ppm monomethyl ether hydroquinone as inhibitor

반응 적합성

reagent type: cross-linking reagent
reaction type: Polymerization Reactions

refractive index

n20/D 1.454 (lit.)

bp

98-100 °C/5 mmHg (lit.)

density

1.051 g/mL at 25 °C (lit.)

Ω-끝

methacrylate

α-끝

methacrylate

폴리머 구조

shape: linear
functionality: homobifunctional

저장 온도

2-8°C

SMILES string

CC(=C)C(=O)OCCOC(=O)C(C)=C

InChI

1S/C10H14O4/c1-7(2)9(11)13-5-6-14-10(12)8(3)4/h1,3,5-6H2,2,4H3

InChI key

STVZJERGLQHEKB-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Ethylene glycol dimethylacrylate (EGDMA) is a diester formed by condensation of two equivalents of methacrylic acid and one equivalent of ethylene glycol.

애플리케이션

Ethylene glycol dimethacrylate can be used as a cross-linker in thepreparation of:

  • A terpolymer system, poly(acrylonitrile-co-Ethyleneglycol dimethacrylate-co-vinylbenzyl chloride), which is applicable as a sorbentin pharmaceuticals adsorption.
  • PVA (polyvinyl alcohol) based hydrogel by free-radicalcopolymerization. These PVA polymer networks can be used as drug deliverysystems.
It can also be used asa monomer in the preparation of swellable and non-swellable poly(ethyleneglycol dimethacrylate/acrylic acid) copolymer microspheres through suspensionpolymerization.

픽토그램

Exclamation mark

신호어

Warning

유해 및 위험 성명서

Hazard Classifications

Skin Sens. 1 - STOT SE 3

표적 기관

Respiratory system

Storage Class Code

10 - Combustible liquids

WGK

WGK 1

Flash Point (°F)

219.2 °F - Pensky-Martens closed cup

Flash Point (°C)

104 °C - Pensky-Martens closed cup

개인 보호 장비

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Robert H Utama et al.
Chemical communications (Cambridge, England), 48(90), 11103-11105 (2012-10-09)
Hollow polymeric nanoparticles with a hydrophilic liquid core have been synthesized in a one-pot approach via a novel inverse miniemulsion periphery RAFT polymerization process. Successful encapsulation and release of a model protein is reported as a potential application.
Andreia F R Pimenta et al.
PloS one, 11(12), e0167728-e0167728 (2016-12-10)
The study of ocular drug delivery systems has been one of the most covered topics in drug delivery research. One potential drug carrier solution is the use of materials that are already commercially available in ophthalmic lenses for the correction
Xinglin Lu et al.
Proceedings of the National Academy of Sciences of the United States of America, 114(46), E9793-E9801 (2017-10-29)
The cytotoxicity of 2D graphene-based nanomaterials (GBNs) is highly important for engineered applications and environmental health. However, the isotropic orientation of GBNs, most notably graphene oxide (GO), in previous experimental studies obscured the interpretation of cytotoxic contributions of nanosheet edges.
Mariane Gonçalves Santos et al.
Talanta, 163, 8-16 (2016-11-26)
The use of a new class of hybrid materials, called restricted access molecularly imprinted polymers (RAMIPs) seems to present a good strategy for the sample preparation of complex matrices, since these materials combine good protein elimination capacity with high degree
Zhen Wang et al.
Electrophoresis, 33(21), 3151-3158 (2012-09-06)
A microfluidic device that performs "in space" sample fractionation, collection, and preconcentration for proteomics is described. Effluents from a 2.75 mm long fractionation channel, focused via sheath flow, were sequentially delivered into an array of 36-collection channels containing monolithic polymer

문서

Monomers for ophthalmic use aim for purity, reliability, and comfort, driving innovation for affordable contact lenses.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..