추천 제품
Grade
anhydrous
vapor density
2.39 (vs air)
vapor pressure
18.81 psi ( 55 °C)
5.5 psi ( 20 °C)
5.69 psi ( 20 °C)
분석
99.8%
형태
liquid
autoignition temp.
1256 °F
불순물
<0.002% water
<0.005% water (100 mL pkg)
증발 잔류물
<0.0005%
refractive index
n20/D 1.358 (lit.)
bp
47-48 °C (lit.)
mp
−35 °C (lit.)
density
1.57 g/mL at 25 °C (lit.)
SMILES string
FC(F)(Cl)C(F)(Cl)Cl
InChI
1S/C2Cl3F3/c3-1(4,6)2(5,7)8
InChI key
AJDIZQLSFPQPEY-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
포장
Packaged under nitrogen in Sure/Seal™ bottles
법적 정보
Genetron is a registered trademark of Honeywell International Inc.
Sure/Seal is a trademark of Sigma-Aldrich Co. LLC
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Aquatic Chronic 2 - Eye Irrit. 2 - Ozone 1
Storage Class Code
10 - Combustible liquids
WGK
WGK 2
Flash Point (°F)
383.0 °F
Flash Point (°C)
195 °C
개인 보호 장비
Eyeshields, Gloves, multi-purpose combination respirator cartridge (US)
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
International archives of occupational and environmental health, 70(3), 187-194 (1997-01-01)
The objectives of this study were threefold. First, to examine the hepatic effects of occupational exposure to 1,1,2-trichloro-1,2,2-trifluoroethane (FC 113) using conventional and newer tests (serum bile acids) of hepatobiliary function. Second, to assess the effects of altered work practices
Toxicology and industrial health, 6(3-4), 493-498 (1990-05-01)
The interaction of Freon 113 (1,1,2-trichloro-1,2,2-trifluoroethane) and hypoxia on the heart conduction system was studied using electrocardiogram monitoring of isolated perfused rat hearts. Freon 113 (0.2 mM) alone elicited significant atrioventricular conduction delay (p less than 0.05) and heart rate
American journal of industrial medicine, 25(5), 731-735 (1994-05-01)
Two cases of atrial fibrillation and one case of sudden death occurred in workers exposed to trifluorotrichloroethane (CFC 113) as a solvent/degreasing agent. This agent and related halogenated hydrocarbons are widely used in industry as solvents and degreasing agents, and
American Industrial Hygiene Association journal, 51(7), 395-401 (1990-07-01)
Results obtained using the Fourier transform infrared spectrophotometer (FTIR) and the Miniature Infrared Analyzer (MIRAN) for samples of workplace air containing trichloroethylene (TCE) were evaluated through comparison with results obtained when using a gas chromatography (GC). The effects of instrument
Clinical biochemistry, 14(2), 51-56 (1981-04-01)
We have evaluated a partially automated Behring laser nephelometer for the measurement of IgG, IgA, IgM and C3c in serum. The system consisted of a manual Behring laser nephelometer, an automatic cuvette carrier and a Hewlett-Packard 9815 A calculator/printer. The
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.