콘텐츠로 건너뛰기
Merck
모든 사진(2)

문서

203033

Sigma-Aldrich

Cesium iodide

99.999% trace metals basis

동의어(들):

Caesium iodide, Caesium monoiodide

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
CsI
CAS Number:
Molecular Weight:
259.81
EC Number:
MDL number:
UNSPSC 코드:
12352302
eCl@ss:
38100503
PubChem Substance ID:
NACRES:
NA.23

분석

99.999% trace metals basis

형태

solid

불순물

≤15.0 ppm Trace Metal Analysis

mp

626 °C (lit.)

density

4.51 g/mL at 25 °C (lit.)

SMILES string

[I-].[Cs+]

InChI

1S/Cs.HI/h;1H/q+1;/p-1

InChI key

XQPRBTXUXXVTKB-UHFFFAOYSA-M

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Cesium iodide can be used as precursor to synthesize lead-free perovskite material, Cs2NaBiI6 (CNBI). The CNBI is highly stable and finds application in the field of solar cells, LEDs, and lasers.

It can be used to prepare brightest red emitting Cs2HfI6 scintillator which is applicable in high resolution gamma spectroscopy.

It can also be used tosynthesize Cesium based nanocrystals for the detection of ionizingradiations.

특징 및 장점

  • High quantum efficiency
  • High stability to ambient air and gas environment
Frequently used in devices such as phosphor screens for medical imaging, scintillators, calorimeters and a variety of particle detectors.

픽토그램

Health hazardEnvironment

신호어

Warning

유해 및 위험 성명서

Hazard Classifications

Aquatic Acute 1 - Repr. 2

Storage Class Code

13 - Non Combustible Solids

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

dust mask type N95 (US), Eyeshields, Faceshields, Gloves


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Marco Bertolini et al.
Medical physics, 39(5), 2617-2627 (2012-05-09)
The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer
G Hajdok et al.
Medical physics, 35(7), 3194-3204 (2008-08-14)
A frequency-dependent x-ray Swank factor based on the "x-ray interaction" modulation transfer function and normalized noise power spectrum is determined from a Monte Carlo analysis. This factor was calculated in four converter materials: amorphous silicon (a-Si), amorphous selenium (a-Se), cesium
Mowei Zhou et al.
Analytical chemistry, 84(14), 6016-6023 (2012-07-04)
A custom in-line surface-induced dissociation (SID) device has been incorporated into a commercial ion mobility quadrupole/time-of-flight mass spectrometer in order to provide an alternative and potentially more informative activation method than the commonly used collision-induced dissociation (CID). Complicated sample mixtures
Melanie Freed et al.
Medical physics, 37(6), 2593-2605 (2010-07-17)
Accurate models of detector blur are crucial for performing meaningful optimizations of three-dimensional (3D) x-ray breast imaging systems as well as for developing reconstruction algorithms that faithfully reproduce the imaged object anatomy. So far, x-ray detector blur has either been
Nobuhiro Yasui et al.
Advanced materials (Deerfield Beach, Fla.), 24(40), 5464-5469 (2012-08-14)
Alkali halide systems that function as phase-separated scintillators (PSSs) with light-guiding properties are sucessfully created. Furthermore, it is the matrix phases of the PSSs which display the light-guiding properties. CsI-NaCl:Tl is a practical material pair because of its high pixel

문서

Colloidal quantum dots (CQDs) are semiconducting crystals of only a few nanometers (ca. 2–12 nm) coated with ligand/surfactant molecules to help prevent agglomeration.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.