コンテンツへスキップ
Merck
  • The influence of polymer topology on pharmacokinetics: differences between cyclic and linear PEGylated poly(acrylic acid) comb polymers.

The influence of polymer topology on pharmacokinetics: differences between cyclic and linear PEGylated poly(acrylic acid) comb polymers.

Journal of controlled release : official journal of the Controlled Release Society (2009-05-26)
Bo Chen, Katherine Jerger, Jean M J Fréchet, Francis C Szoka
要旨

Water-soluble polymers for the delivery of chemotherapeutic drugs passively target solid tumors as a consequence of reduced renal clearance and the enhanced permeation and retention (EPR) effect. Elimination of the polymers in the kidney occurs due to filtration through biological nanopores with a hydrodynamic diameter comparable to the polymer. Therefore we have investigated chemical features that may broadly be grouped as "molecular architecture" such as: molecular weight, chain flexibility, number of chain ends and branching, to learn how they impact polymer elimination. In this report we describe the synthesis of four pairs of similar molecular weight cyclic and linear polyacrylic acid polymers grafted with polyethylene glycol (23, 32, 65, 114 kDa) with low polydispersities using ATRP and "click" chemistry. The polymers were radiolabeled with (125)I and their pharmacokinetics and tissue distribution after intravenous injection were determined in normal and C26 adenocarcinoma tumored BALB/c mice. Cyclic polymers above the renal threshold of 30 kDa had a significantly longer elimination time (between 10 and 33% longer) than did the comparable linear polymer (for the 66 kDa cyclic polymer, t(1/2,beta)=35+/-2 h) and a greater area under the serum concentration versus time curve. This resulted in a greater tumor accumulation of the cyclic polymer than the linear polymer counterpart. Thus water-soluble cyclic comb polymers join a growing list of polymer topologies that show greatly extended circulation times compared to their linear counterparts and provide alternative polymer architecture for use as drug carriers.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
ポリ(メタクリル酸メチル), average Mw ~350,000 by GPC
Sigma-Aldrich
ポリ(メタクリル酸メチル)
Sigma-Aldrich
ポリ(メタクリル酸メチル), average Mw ~15,000 by GPC, powder
Sigma-Aldrich
ポリ(メタクリル酸メチル)
Supelco
ポリ(メタクリル酸メチル), analytical standard, for GPC, 2,000
Supelco
ポリ(メタクリル酸メチル), analytical standard, for GPC, 100,000
Supelco
ポリ(メタクリル酸メチル), analytical standard, for GPC, 10,000
Supelco
ポリ(メタクリル酸メチル), analytical standard, for GPC, 50,000
Supelco
ポリ(メタクリル酸メチル), analytical standard, for GPC, 20,000
Supelco
ポリ(メタクリル酸メチル), analytical standard, for GPC, 2,480,000
Supelco
ポリ(メタクリル酸メチル), analytical standard, for GPC, average Mw 97,000 (Typical), average Mn 46,000 (Typical)
Sigma-Aldrich
ポリ(メタクリル酸メチル), CP
Supelco
ポリ(メタクリル酸メチル), analytical standard, for GPC, 4,000
Supelco
ポリ(メタクリル酸メチル), analytical standard, for GPC, 8,000