コンテンツへスキップ
Merck

LNEHBA1C403

HbA1c in lyophilized hemolysates

LNE Certified Reference Material, commutable, JCTLM listed

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
41116107
NACRES:
NA.24

形状

liquid

品質

commutable, JCTLM listed

シェルフライフ

limited shelf life, expiry date on the label

組成

lyophilized human blood hemolysates, 100%

体外診断薬

not for in vitro diagnostic use

保管温度

2-8°C

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

LNE CRM HbA1c 403 is a higher-order certified reference material produced by the French metrological institute LNE in compliance with ISO 17034 requirements. This Certified Reference Material LNE CRM HbA1c 403 corresponds to lyophilized human blood hemolysates and is intended for use as quality control materials for the verification of the accuracy of the reference method and routine methods used in clinical laboratories for the quantification of HbA1c in hemolysate or whole blood. Sample commutability was assessed through an extensive study involving seventeen of the most used method for the quantification of HbA1c in clinical laboratory using the difference in bias approach described in the IFCC recommendations on commutability assessment. Commutability results are reported in the certificate of analysis.

Cert_ LNE CRM HbA1c 403

アプリケーション

HbA1c in lyophilized hemolysates (LNE CRM HbA1c 403) is intended for use as quality control material to assess the measurement bias or measurement uncertainty of established or new measurement procedures for the determination of HbA1c in hemolysate or whole blood.

特徴および利点

  • This certified reference material (CRM) ensures accurate HbA1c measurement in clinical diagnostic assays. 
  • The HbA1c concentration of this material is certified using the IFCC reference method via LC/MS and is derived from real patient samples.
  • This CRM is pooled, tested, and certified by the LNE, which includes extensive commutability studies. 
  • Commutability is assessed for the main routine assays. 
  • Target values are certified using higher-order reference methods that are calibrated using primary standards of certified purity or certified reference materials, which allows the establishment of metrological traceability of results to the SI units. 
  • The accuracy of the reference methods used to certify target values is verified using certified matrix reference materials. 
  • Certified reference materials referenced by the JCTLM as higher order standards. 

その他情報

  • Details on storage, safety, usage, and operating instructions are provided in the comprehensive Certificate of Analysis. 
  • This clinical matrix CRM is for research and clinical testing applications. 

保管分類コード

10 - Combustible liquids

WGK

WGK 1

引火点(°F)

Not applicable

引火点(℃)

Not applicable


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

LNEHBA1C403-1EA:


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)