おすすめの製品
形状
liquid
品質
commutable, JCTLM listed
シェルフライフ
limited shelf life, expiry date on the label
組成
lyophilized human blood hemolysates, 100%
体外診断薬
not for in vitro diagnostic use
保管温度
2-8°C
類似した製品をお探しですか? 訪問 製品比較ガイド
関連するカテゴリー
詳細
LNE CRM HbA1c 403 is a higher-order certified reference material produced by the French metrological institute LNE in compliance with ISO 17034 requirements. This Certified Reference Material LNE CRM HbA1c 403 corresponds to lyophilized human blood hemolysates and is intended for use as quality control materials for the verification of the accuracy of the reference method and routine methods used in clinical laboratories for the quantification of HbA1c in hemolysate or whole blood. Sample commutability was assessed through an extensive study involving seventeen of the most used method for the quantification of HbA1c in clinical laboratory using the difference in bias approach described in the IFCC recommendations on commutability assessment. Commutability results are reported in the certificate of analysis.
Cert_ LNE CRM HbA1c 403
Cert_ LNE CRM HbA1c 403
アプリケーション
HbA1c in lyophilized hemolysates (LNE CRM HbA1c 403) is intended for use as quality control material to assess the measurement bias or measurement uncertainty of established or new measurement procedures for the determination of HbA1c in hemolysate or whole blood.
特徴および利点
- This certified reference material (CRM) ensures accurate HbA1c measurement in clinical diagnostic assays.
- The HbA1c concentration of this material is certified using the IFCC reference method via LC/MS and is derived from real patient samples.
- This CRM is pooled, tested, and certified by the LNE, which includes extensive commutability studies.
- Commutability is assessed for the main routine assays.
- Target values are certified using higher-order reference methods that are calibrated using primary standards of certified purity or certified reference materials, which allows the establishment of metrological traceability of results to the SI units.
- The accuracy of the reference methods used to certify target values is verified using certified matrix reference materials.
- Certified reference materials referenced by the JCTLM as higher order standards.
その他情報
- Details on storage, safety, usage, and operating instructions are provided in the comprehensive Certificate of Analysis.
- This clinical matrix CRM is for research and clinical testing applications.
保管分類コード
10 - Combustible liquids
WGK
WGK 1
引火点(°F)
Not applicable
引火点(℃)
Not applicable
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
LNEHBA1C403-1EA:
最新バージョンのいずれかを選択してください:
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)