おすすめの製品
由来生物
goat
品質水準
抗体製品の状態
affinity isolated antibody
抗体製品タイプ
secondary antibodies
クローン
polyclonal
形状
buffered aqueous solution
化学種の反応性
rabbit
濃度
~1 mg/mL
蛍光検出
λex 587 nm; λem 607 nm in PBS, pH 7.4
保管温度
−20°C
詳細
Abberior STAR 580 was developed for STED and confocal microscopy in the orange spectral region. Abberior STAR 580 is highly photostable and bright orange fluorescent dye. The dye works extremely well with Abberior Instruments STEDYCON and Expert Line Microscopes and Leica STED microscopes. It can be very effectively excited with excitation wavelength between 550 - 600 nm. Abberior STAR 580 can substitute dyes like Cy3™, Atto™ 590 or Alexa Fluor™ 568. For STED microscopy, Abberior STAR 580 can be used most efficiently with a STED Laser wavelength between 750 - 800 nm. Abberior STAR 580 is the ideal partner for Abberior STAR RED or Abberior STAR 635P to obtain optimal 2 Color STED results. Best results are obtained with freshly prepared samples.
Photophysical properties (carboxylic acid):
Absorption Maximum, λex [nm]: 587 (PBS pH 7.4), 584 (H2O), 584 (MeOH)
Extinction Coefficient, εmax [M-1cm-1]: 85 000 (PBS pH 7.4), 85 000 (H2O), 95 000 (MeOH)
Correction Factor, CF260 = ε260/εmax: 0,17 (PBS pH 7.4)
Correction Factor, CF280 = ε280/εmax: 0,17 (PBS pH 7.4)
Fluorescence Maximum, λem [nm]: 607 (PBS pH 7.4), 607 (H2O), 604 (MeOH)
Recommended STED Wavelength, λ [nm]: 750-800
Fluorescence Quantum Yield, λ: 0,90 (PBS pH 7.4)
Fluorescence Lifetime, τ [ns]: 3,5 (PBS pH 7.4)
Photophysical properties (carboxylic acid):
Absorption Maximum, λex [nm]: 587 (PBS pH 7.4), 584 (H2O), 584 (MeOH)
Extinction Coefficient, εmax [M-1cm-1]: 85 000 (PBS pH 7.4), 85 000 (H2O), 95 000 (MeOH)
Correction Factor, CF260 = ε260/εmax: 0,17 (PBS pH 7.4)
Correction Factor, CF280 = ε280/εmax: 0,17 (PBS pH 7.4)
Fluorescence Maximum, λem [nm]: 607 (PBS pH 7.4), 607 (H2O), 604 (MeOH)
Recommended STED Wavelength, λ [nm]: 750-800
Fluorescence Quantum Yield, λ: 0,90 (PBS pH 7.4)
Fluorescence Lifetime, τ [ns]: 3,5 (PBS pH 7.4)
適合性
Designed and tested for fluorescent super-resolution microscopy
アナリシスノート
May contain significant amounts of BSA as stabilizer
unconjugated dye ≤5% of total fluorescence
unconjugated dye ≤5% of total fluorescence
法的情報
ALEXA FLUOR is a trademark of Life Technologies
Atto is a trademark of Atto-Tec GmbH
Cy3 is a trademark of Cytiva
abberior is a registered trademark of Abberior GmbH
適切な製品が見つかりませんか。
製品選択ツール.をお試しください
保管分類コード
12 - Non Combustible Liquids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
Communications biology, 6(1), 358-358 (2023-04-04)
Two prominent concepts for the sensing of shear stress by endothelium are the PIEZO1 channel as a mediator of mechanically activated calcium ion entry and the PECAM1 cell adhesion molecule as the apex of a triad with CDH5 and VGFR2.
ACS nano, 6(6), 4580-4584 (2012-06-19)
Plasmonics and near-field optical nanoscopy both deal with expanding optics into the subwavelength regime. However, these two fields have so far followed parallel paths of development and only recently have researchers started to explore combinations of their concepts with potential
Nature communications, 13(1), 7452-7452 (2022-12-03)
The resolution of fluorescence microscopy images is limited by the physical properties of light. In the last decade, numerous super-resolution microscopy (SRM) approaches have been proposed to deal with such hindrance. Here we present Mean-Shift Super Resolution (MSSR), a new
JACS Au, 3(8), 2247-2256 (2023-09-01)
Polo-like kinase (Plk4) is a serine/threonine-protein kinase that is essential for biogenesis of the centriole organelle and is enriched at centrioles. Herein, we introduce Cen-TCO, a chemical probe based on the Plk4 inhibitor centrinone, to image Plk4 and centrioles in
The Journal of cell biology, 222(7) (2023-05-18)
Endosomal Sorting Complex Required for Transport (ESCRT) proteins can be transiently recruited to the plasma membrane for membrane repair and formation of extracellular vesicles. Here, we discovered micrometer-sized worm-shaped ESCRT structures that stably persist for multiple hours at the plasma
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)