KHVEG03HH3
ミリポアエクスプレス(Millipore Express)®SHRP、オプティキャップ(Opticap)®XLカプセル
inlet connection diam. 9/16 in., Opticap® XL 300, pore size 0.5/0.1 μm, cartridge nominal length 3 in. (7.5 cm)
別名:
Opticap Gamma Compatible XL 3 Millipore Express SHR with prefilter 0.5/0.1 μm 9/16 in. HB/HB
About This Item
おすすめの製品
物質
polyester support
polyethersulfone
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap (Gamma stable)
polysulfone
silicone seal
品質水準
法規制遵守
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
無菌性
non-sterile
滅菌適合性
gamma compatible
製品種目
Opticap® XL 300
特徴
gamma compatible
hydrophilic
メーカー/製品名
Millipore Express®
パラメーター
≤7.3 mL/min air diffusion at 3.45 bar (50 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
テクニック
sterile filtration: suitable
L
17.3 cm (6.8 in.)
W
4.2 in.
カートリッジの長さ(公称)
3 in. (7.5 cm)
直径
12.4 cm (4.12 in.)
ろ過面積
0.13 m2
入口接続部直径
9/16 in.
入口幅・出口幅
17.3 cm (6.8 in.)
出口接続部直径
9/16 in.
不純物
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
マトリックス
Millipore Express® SHR (w/Prefilter)
pore size
0.5/0.1 μm pore size
泡立ち点
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C
フィッティング
1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet hose barb
outlet hose barb
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)
詳細
包装
その他情報
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
調製ノート
ガンマ対応 45 kGyまで; 123 °C 60 分のオートクレーブ滅菌3回; インライン蒸気滅菌不可
アナリシスノート
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 5.5 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
法的情報
免責事項
適切な製品が見つかりませんか。
製品選択ツール.をお試しください
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)