物質
polyethersulfone
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
polysulfone
silicone seal
品質水準
法規制遵守
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
無菌性
non-sterile
滅菌適合性
autoclavable compatible
製品種目
Opticap® XL 3
特徴
hydrophilic
メーカー/製品名
Millipore Express®
パラメーター
≤7.3 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
テクニック
sterile filtration: suitable
L
17.3 cm (6.8 in.)
W
4.2 in.
カートリッジの長さ(公称)
3 in. (7.5 cm)
直径
10.7 cm (4.2 in.)
ろ過面積
0.13 m2
入口接続部直径
1.5 in.
入口幅・出口幅
17.3 cm (6.8 in.)
出口接続部直径
1 in.
不純物
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
マトリックス
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
泡立ち点
≥4000 mbar (58 psig), air with water at 23 °C
フィッティング
1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet hose barb
(38 mm (1 1/2 in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)
詳細
包装
その他情報
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
調製ノート
126 °C 60 分のオートクレーブ滅菌3回; インライン蒸気滅菌不可
アナリシスノート
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 5.5 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.