Skip to Content
Merck
All Photos(4)

Documents

Safety Information

DUO96030

Sigma-Aldrich

Duolink® PLA Multicolor Probemaker Kit - Orange

Proximity Ligation Assay Multiplexing: protein-protein interaction, post-translational modification and low abundant protein events

Synonym(s):

in situ Proximity Ligation Assay Kit, Protein Protein Interaction Kit

Sign Into View Organizational & Contract Pricing


About This Item

UNSPSC Code:
41105331
NACRES:
NA.32

product line

Duolink®

technique(s)

immunofluorescence: suitable
multiplexing: suitable
proximity ligation assay: suitable

fluorescence

λex 542 nm; λem 562 nm (orange)
λex 542 nm; λem 562 nm

suitability

suitable for fluorescence

shipped in

dry ice

storage temp.

−20°C

Application

Specificity
Orange fluorescence detection reagents are often used with Cy®3 filter.

Application Note
Primary antibodies are needed. Test your primary antibodies (IgG-class, mono- or polyclonal) in a standard immunofluorescence (IF), immunohistochemistry (IHC), or immunocytochemistry (ICC) assay to determine the optimal fixation, blocking, and titer conditions. Duolink® in situ reagents are suitable for use on fixed cells, cytospin cells, cells grown on slide, formalin-fixed, paraffin embedded (FFPE), or tissue (fresh or frozen). No minimum number of cells is required.

Let us do the work for you, learn more about our Custom Service Program to accelerate your Duolink® projects

View full Duolink® product list

Features and Benefits

Multicolor Duolink® proximity ligation assay (PLA®) is an application of the Duolink® technology that allows for endogenous, simultaneous detection of up to 4 protein interactions, post-translational modifications, or protein expression levels (including low abundant protein) in fixed cells and tissue samples. Follow the Duolink® PLA Probemaker Guide for Multicolor Detection and the Duolink® PLA Multicolor Detection protocol to use this product.

  • Visualize and detect multiple proteins events in one experiment.
  • No overexpression or genetic manipulation required
  • High specificity (fewer false positives)
  • Detection of low abundant proteins due to rolling circle amplification
  • Relative quantification possible
  • No special equipment needed
  • Faster and more simple than FRET
  • Increased accuracy compared to co-IP
  • Publication-ready results

Components
Duolink® PLA Multicolor Probemaker Kit - Orange contains all the necessary reagents to perform the conjugations of Orange Oligo F and Orange Oligo G directly to primary antibodies. The resulting PLA probes (Orange F and Orange G) must be used together and cannot be paired with any other Duolink® PLA probe.

This product is comprised of the following:
  • Orange Oligo F DUO86030F
  • Orange Oligo G DUO86030G
  • Conjugation Buffer DUO82033
  • Stop Reagent DUO82034
  • Storage Solution DUO82035

See datasheet for more information.

To perform a Multicolor Duolink® PLA experiment primary antibodies (PLA, IHC, ICC or IF validated) that recognize protein targets of interest are required. Duolink® PLA Multicolor Probemaker-generated probes (Red A/Red B, Green C/Green D, Orange F/Orange G, and/or FarRed H/FarRed I) are used in combination to perform the Multiplex experiment.The reagents in the Duolink® PLA Multicolor Reagent Pack are required to perform the amplification and detection of the resulting PLA probes. Required additional reagents include Duolink® Wash Buffers and Mounting Medium.

Legal Information

Cy is a registered trademark of Cytiva
Duolink is a registered trademark of Merck KGaA, Darmstadt, Germany
PLA is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictograms

Exclamation markEnvironment

Signal Word

Warning

Hazard Statements

Hazard Classifications

Aquatic Chronic 2 - Skin Sens. 1

Storage Class Code

10 - Combustible liquids

WGK

WGK 3


Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

PDSCL

Please refer to KIT Component information

PRTR

Please refer to KIT Component information

FSL

Please refer to KIT Component information

ISHL Indicated Name

Please refer to KIT Component information

ISHL Notified Names

Please refer to KIT Component information

Cartagena Act

Please refer to KIT Component information

JAN Code

キットコンポーネントの情報を参照してください


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Articles

Duolink® PLA Multicolor technology and the quantification of protein-protein interactions in fixed tissues and cells.

Protocols

Duolink® PLA Multicolor Detection Protocol

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service