grade

ACS reagent

Quality Level

Agency

reag. ISO
reag. Ph. Eur.
suitable for SM 2310
suitable for SM 2320
suitable for SM 4500 - NH3

product line

EMSURE®

Assay

99.5-101.0% (iodometric)

form

solid

potency

>5000 mg/kg LD50, oral (Rat)

impurities

≤0.005% Insoluble matter

pH

6.0-7.5 (20 °C, 100 g/L in H2O)

mp

48 °C

density

1.74 g/cm3 at 20 °C

bulk density

1000 kg/m3

anion traces

chloride (Cl-): ≤0.008%
sulfate, sulfite (as SO42-): ≤0.1%
sulfide (S2-): passes test

cation traces

Ca: ≤0.002%
Cu: ≤0.0005%
Fe: ≤0.0005%
K: ≤0.001%
Mg: ≤0.001%
N: ≤0.002%
Pb: ≤0.0005%
heavy metals (as Pb): ≤0.001%

storage temp.

2-30°C

InChI

1S/2Na.H2O3S2.5H2O/c;;1-5(2,3)4;;;;;/h;;(H2,1,2,3,4);5*1H2/q2*+1;;;;;;/p-2

InChI key

PODWXQQNRWNDGD-UHFFFAOYSA-L

Looking for similar products? Visit Product Comparison Guide

Related Categories

Application


  • Synthesis of Aryl Amides from Acyl-Bunte Salts and Aryl Azides: Details the application of sodium thiosulfate pentahydrate in synthetic organic chemistry, specifically in the synthesis of aryl amides, illustrating its utility in facilitating complex chemical reactions (Chen et al., 2023).

Linkage

Replaces: SX0815-1; SX0815

Analysis Note

Assay (iodometric): 99.5 - 101.0 %
Identity: passes test
Appearance of solution: passes test
Insoluble matter: ≤ 0.005 %
pH-value (5 %; water, 25 °C): 6.0 - 7.5
pH-value (10 %; water): 6.0 - 7.5
Chloride (Cl): ≤ 0.008 %
Sulfate and sulphite (as SO₄): ≤ 0.1 %
Sulfide (S): passes test
Heavy metals (as Pb): ≤ 0.001 %
Total nitrogen (N): ≤ 0.002 %
Ca (Calcium): ≤ 0.002 %
Cu (Copper): ≤ 0.0005 %
Fe (Iron): ≤ 0.0005 %
K (Potassium): ≤ 0.001 %
Mg (Magnesium): ≤ 0.001 %
Pb (Lead): ≤ 0.0005 %
Corresponds to ACS, ISO, Reag. Ph Eur

Legal Information

EMSURE is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

13 - Non Combustible Solids

WGK

WGK 1

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Related Content

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service