Skip to Content
Merck
All Photos(1)

Documents

MPGPG02A1

Milli-Q

Millipak® Gold Filter

For particulates- and bacteria-free water at the point of dispense of the Milli-Q® 7 series water purification systems.

Synonym(s):

Millipak® Gold 0.22 μm Sterile Filter

Sign Into View Organizational & Contract Pricing


About This Item

UNSPSC Code:
41104212
eCl@ss:
33050190
NACRES:
NB.24

material

polyethersulfone filter

Quality Level

sterility

sterile

feature

hydrophilic

packaging

pkg of 1 unit

manufacturer/tradename

Millipak®

outlet connection diam.

1/4 in.

pore size

0.22 μm pore size

fitting

outlet stepped hose barb (with bell)

compatibility

for use with Milli-Q® EQ 7000
for use with Milli-Q® EQ 7008
for use with Milli-Q® EQ 7016
for use with Milli-Q® IX 7003
for use with Milli-Q® IX 7005
for use with Milli-Q® IX 7010
for use with Milli-Q® IX 7015
for use with Milli-Q® IQ 7000
for use with Milli-Q® IQ 7003
for use with Milli-Q® IQ 7005
for use with Milli-Q® IQ 7010
for use with Milli-Q® IQ 7015

shipped in

ambient

Looking for similar products? Visit Product Comparison Guide

General description

Millipak® Gold 0.22 μm sterile filter is a lab water consumable made up of PES (polyethersulfone) that is exclusively designed to remove particulates and bacteria from purified water. Here, the water is purified by filtering through a 0.22 μm sterilizing-grade membrane.
The membrane in the Millipak® filter consists of conical pores that allow the water to filter at a higher flow rate with low differential pressure. The filter is heat-sealed on SAN (styrene-acrylonitrile) housing material. The housing material, along with the membrane and the production processes are carefully chosen to reduce organic and inorganic extractable release.
Millipak® Gold 0.22 μm sterile filter is suitable for use with Milli-Q® IQ 7000, Milli-Q® IQ 7003/05/10/15, Milli-Q® IX 7003/05/10/15 and Milli-Q® EQ 7000/08/16 water purification systems.

Application

Millipak® Gold 0.22 μm sterile filter when fed with Milli-Q® purified water is used in a variety of laboratory applications including cell culture and microbiology.

Features and Benefits

  • Each Millipak® Gold 0.22 μm filter is individually tested, hermetically sealed and delivered with a Certificate of Quality.
  • Delivers bacteria-free water at <0.01 cfu/mL when installed and used in a laminar flow hood.
  • Delivers particulate-free water (no particles with size >0.22 μm).
  • Carefree maintenance: Easily installed and replaced.
  • Redesigned bottom-tip for a secured installation of the protection bell.
  • e-Sure tag for RFID connection with E-POD® or Q-POD® dispenser enables full traceability (data management) and automatic consumable status monitoring on the POD′s touchscreen interface.

Other Notes

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganisms
  • Mode of Action: Filtering
  • Application: General laboratory analysis
  • Intended Use: Water purification
  • Instructions for Use: This item provides water filtered through 0.22 μm sterilizing-grade membranes. Refer to the system equipment user guide section "Using the System" (available on USB key in the system box).
  • Storage Statement: Store in a dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Legal Information

E-POD is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPAK is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany
Q-POD is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

11 - Combustible Solids


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Articles

Discover the importance of water quality in microbiology and its impact on reliable and reproducible results in culture media preparation. Learn about the EN ISO 11133 standard, lab water solutions, and purification technologies recommended for microbiological testing.

Discover the importance of water quality in microbiology and its impact on reliable and reproducible results in culture media preparation. Learn about the EN ISO 11133 standard, lab water solutions, and purification technologies recommended for microbiological testing.

Discover the importance of water quality in microbiology and its impact on reliable and reproducible results in culture media preparation. Learn about the EN ISO 11133 standard, lab water solutions, and purification technologies recommended for microbiological testing.

Discover the importance of water quality in microbiology and its impact on reliable and reproducible results in culture media preparation. Learn about the EN ISO 11133 standard, lab water solutions, and purification technologies recommended for microbiological testing.

See All

Related Content

Milli-Q® ultrapure water systems ensure reliable science, with an expanded system offer catering to diverse lab needs and constraints.

Milli-Q® ultrapure water systems ensure reliable science, with an expanded system offer catering to diverse lab needs and constraints.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service