Skip to Content
Merck
All Photos(3)

Documents

335681

Sigma-Aldrich

Ethylene glycol dimethacrylate

98%, cross-linking reagent polymerization reactions, methacrylate, 90-110 ppm monomethyl ether hydroquinone as inhibitor

Synonym(s):

Polyethylene glycol, 1,2-Ethanediol dimethacrylate, Ethylene dimethacrylate

Sign Into View Organizational & Contract Pricing


About This Item

Linear Formula:
CH2=C(CH3)COOCH2CH2OCOC(CH3)=CH2
CAS Number:
Molecular Weight:
198.22
Beilstein:
1776663
EC Number:
MDL number:
UNSPSC Code:
12162002
PubChem Substance ID:
NACRES:
NA.23

product name

Ethylene glycol dimethacrylate, 98%, contains 90-110 ppm monomethyl ether hydroquinone as inhibitor

vapor density

>1 (vs air)

Quality Level

vapor pressure

<0.1 mmHg ( 21.1 °C)

Assay

98%

form

liquid

contains

90-110 ppm monomethyl ether hydroquinone as inhibitor

reaction suitability

reagent type: cross-linking reagent
reaction type: Polymerization Reactions

refractive index

n20/D 1.454 (lit.)

bp

98-100 °C/5 mmHg (lit.)

density

1.051 g/mL at 25 °C (lit.)

Ω-end

methacrylate

α-end

methacrylate

polymer architecture

shape: linear
functionality: homobifunctional

storage temp.

2-8°C

SMILES string

CC(=C)C(=O)OCCOC(=O)C(C)=C

InChI

1S/C10H14O4/c1-7(2)9(11)13-5-6-14-10(12)8(3)4/h1,3,5-6H2,2,4H3

InChI key

STVZJERGLQHEKB-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

General description

Ethylene glycol dimethylacrylate (EGDMA) is a diester formed by condensation of two equivalents of methacrylic acid and one equivalent of ethylene glycol.

Application

Ethylene glycol dimethacrylate can be used as a cross-linker in thepreparation of:

  • A terpolymer system, poly(acrylonitrile-co-Ethyleneglycol dimethacrylate-co-vinylbenzyl chloride), which is applicable as a sorbentin pharmaceuticals adsorption.
  • PVA (polyvinyl alcohol) based hydrogel by free-radicalcopolymerization. These PVA polymer networks can be used as drug deliverysystems.
It can also be used asa monomer in the preparation of swellable and non-swellable poly(ethyleneglycol dimethacrylate/acrylic acid) copolymer microspheres through suspensionpolymerization.

Pictograms

Exclamation mark

Signal Word

Warning

Hazard Statements

Hazard Classifications

Skin Sens. 1 - STOT SE 3

Target Organs

Respiratory system

Storage Class Code

10 - Combustible liquids

WGK

WGK 1

Flash Point(F)

219.2 °F - Pensky-Martens closed cup

Flash Point(C)

104 °C - Pensky-Martens closed cup

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Yuan Qi et al.
ACS applied materials & interfaces, 11(32), 28690-28698 (2019-07-20)
Compared with conventional glass slides and two-dimensional (2D) planar microarrays, polymer-based support materials and three-dimensional (3D) surface structures have attracted increasing attention in the field of biochips because of their good processability in microfabrication and low cost in mass production
Kouroush Salimi et al.
Journal of chromatography. A, 1496, 9-19 (2017-03-30)
A seeded polymerization protocol was developed for the synthesis of monodisperse-porous poly(vinylphosphonic acid-co-ethylene dimethacrylate), [poly(VPA-co-EDMA)] microspheres with superior porous properties. The protocol allowed the direct synthesis of phosphonic acid functionalized porous microspheres with the mean size of ∼4μm and the
Xinglin Lu et al.
Proceedings of the National Academy of Sciences of the United States of America, 114(46), E9793-E9801 (2017-10-29)
The cytotoxicity of 2D graphene-based nanomaterials (GBNs) is highly important for engineered applications and environmental health. However, the isotropic orientation of GBNs, most notably graphene oxide (GO), in previous experimental studies obscured the interpretation of cytotoxic contributions of nanosheet edges.
Zhen Wang et al.
Electrophoresis, 33(21), 3151-3158 (2012-09-06)
A microfluidic device that performs "in space" sample fractionation, collection, and preconcentration for proteomics is described. Effluents from a 2.75 mm long fractionation channel, focused via sheath flow, were sequentially delivered into an array of 36-collection channels containing monolithic polymer
Mariane Gonçalves Santos et al.
Talanta, 163, 8-16 (2016-11-26)
The use of a new class of hybrid materials, called restricted access molecularly imprinted polymers (RAMIPs) seems to present a good strategy for the sample preparation of complex matrices, since these materials combine good protein elimination capacity with high degree

Articles

Monomers for ophthalmic use aim for purity, reliability, and comfort, driving innovation for affordable contact lenses.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service