Saltar al contenido
Merck

US EPA Method 8015 (modified): GC Analysis of Diesel Range Organics (DRO) on SLB®-5ms (20 m x 0.18 mm I.D., 0.18 μm), Fast GC Analysis

US EPA Method 8015 (modified): GC Analysis of Diesel Range Organics (DRO) on SLB®-5ms (20 m x 0.18 mm I.D., 0.18 μm), Fast GC Analysis suitable for GC

Materiales

Analytical column

Referencia del producto
Descripción
Precios

SPB®-608

L × I.D. 30 m × 0.25 mm, df 0.25 μm

SPB®-608

L × I.D. 30 m × 0.53 mm, df 0.50

Columna para GC capilar Equity -1701

L × I.D. 30 m × 0.25 mm, df 0.25 μm

Columna para GC capilar Equity -1701

L × I.D. 30 m × 0.25 mm, df 1.00 μm

Columna para GC capilar Equity -1701

L × I.D. 30 m × 0.53 mm, df 0.50 μm

SLB®-5ms Capillary GC Column

L × I.D. 30 m × 0.25 mm, df 0.25 μm

SLB®-5ms Capillary GC Column

L × I.D. 30 m × 0.25 mm, df 1.00 μm

SLB®-5ms Capillary GC Column

L × I.D. 15 m × 0.10 mm, df 0.10 μm

SLB®-5ms Capillary GC Column

L × I.D. 20 m × 0.18 mm, df 0.18 μm

For use with

Referencia del producto
Descripción
Precios

Wheaton wide-mouth bottle

amber soda-lime glass bottle, capacity 1000 mL, white polypropylene cap, (PTFE faced LDPE liner), case of 12 ea

Wheaton straight-mouth bottles with cap, clear

clear soda-lime glass bottle, capacity 250 mL, white polypropylene cap, (PTFE faced LDPE liner), case of 12 ea

Guard column

Referencia del producto
Descripción
Precios

Intermediate Polarity Fused Silica Tubing

L × I.D. 5.0 m × 0.25 mm

Intermediate Polarity Fused Silica Tubing

L × I.D. 5.0 m × 0.53 mm

Optional

Referencia del producto
Descripción
Precios

Polyimide Sealing Resin

pkg of 5 g

Standard

Referencia del producto
Descripción
Precios

Underground Storage Tank (UST) Modified DRO

certified reference material, TraceCERT®, 1000 μg/mL each component in hexane, ampule of 1 mL

required but not provided

Referencia del producto
Descripción
Precios

"Y" GlasSeal Connector, Borosilicate Glass

pkg of 1 ea

"Y" Glassseal Connectors

pkg of 1 ea

"Y" Glassseal Connectors

pkg of 3 ea

CONDITIONS

column

SLB-5ms, 20 m x 0.18 mm I.D., 0.18 μm (28564-U)

oven

50 °C (2 min), 20 °C/min to 325 °C (1 min)

inj. temp.

250 °C

detector

FID, 350 °C

carrier gas

helium, 0.9 mL/min, constant

injection

1 μL, splitless (splitter open at 0.5 min)

liner

2 mm I.D., FocusLiner inlet liner

sample

each analyte at 50 μg/mL in methylene chloride

Descripción

Legal Information

FocusLiner is a trademark of SGE Analytical Science Pty Ltd.
SLB is a registered trademark of Merck KGaA, Darmstadt, Germany