Saltar al contenido
Merck
  • An LC-MS/MS method for the simultaneous determination of goserelin and testosterone in rat plasma for pharmacokinetic and pharmacodynamic studies.

An LC-MS/MS method for the simultaneous determination of goserelin and testosterone in rat plasma for pharmacokinetic and pharmacodynamic studies.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-07-20)
Shu Zhang, Jiangbin Han, Guangyi Leng, Xin Di, Chunjie Sha, Xuemei Zhang, Youxin Li, Wanhui Liu
RESUMEN

A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed, using testosterone-d3 as a surrogate analyte, for the simultaneous quantification of goserelin and testosterone in rat plasma. According to this method, the pharmacokinetic and pharmacodynamic data were obtained from a single plasma sample aliquot. The method involved the addition of alarelin as an internal standard (IS) for goserelin and testosterone-(13)C3 for testosterone or testosterone-d3. The conditions for the separation of these two compounds were achieved on a ZORBAX Eclipse Plus C18 column (Agilent, 2.1 × 50 mm, 1.8 μm, Stockport, UK) in a single chromatographic run at a flow rate of 400 μL/min. In order to minimize interferences of complex matrix, the extraction of plasma consisted of a protein precipitation step using methanol, followed by purification using an Oasis(®) HLB solid-phase extraction column. The method was validated in the concentration range of 0.01-30.0 ng/mL for goserelin and 0.05-30.0 ng/mL for testosterone-d3, respectively. The within- and between-run precisions were 1.7-9.2% and 2.1-6.9%, respectively. The within- and between-run accuracies were -1.8 to 5.3% and -4.9 to 4.0%, respectively. This accurate and highly specific assay provides a useful method to evaluate the pharmacokinetics and pharmacodynamics of goserelin in rats.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Metanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanol, BioReagent, ≥99.93%
Sigma-Aldrich
Metanol, Absolute - Acetone free
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Metanol, anhydrous, 99.8%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Metanol, JIS special grade, ≥99.8%
USP
Metanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Testosterone, ≥98%
Sigma-Aldrich
Metanol, SAJ first grade, ≥99.5%
Supelco
Testosterone solution, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Supelco
Metanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Metanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Supelco
Testosterone-2,3,4-13C3 solution, 100 μg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Metanol, analytical standard
Sigma-Aldrich
Metanol, SAJ special grade
Sigma-Aldrich
Metanol, suitable for HPLC
Sigma-Aldrich
Testosterone-2,3,4-13C3 solution, 0.1 mg/mL in methanol, 99 atom % 13C, 98% (CP)
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, 99.93%
Sigma-Aldrich
Metanol, NMR reference standard
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%