Saltar al contenido
Merck

Particle shedding from peristaltic pump tubing in biopharmaceutical drug product manufacturing.

Journal of pharmaceutical sciences (2015-01-22)
Verena Saller, Julia Matilainen, Ulla Grauschopf, Karoline Bechtold-Peters, Hanns-Christian Mahler, Wolfgang Friess
RESUMEN

In a typical manufacturing setup for biopharmaceutical drug products, the fill and dosing pump is placed after the final sterile filtration unit in order to ensure adequate dispensing accuracy and avoid backpressure peaks. Given the sensitivity of protein molecules, peristaltic pumps are often preferred over piston pumps. However, particles may be shed from the silicone tubing employed. In this study, particle shedding and a potential turbidity increase during peristaltic pumping of water and buffer were investigated using three types of commercially available silicone tubing. In the recirculates, mainly particles of around 200 nm next to a very small fraction of particles in the lower micrometer range were found. Using 3D laser scanning microscopy, surface roughness of the inner tubing surface was found to be a determining factor for particle shedding from silicone tubing. As the propensity toward particle shedding varied between tubing types and also cannot be concluded from manufacturer's specifications, individual testing with the presented methods is recommended during tubing qualification. Choosing low abrasive tubing can help to further minimize the very low particle counts to be expected in pharmaceutical drug products.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Sacarosa, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Sacarosa, ≥99.5% (GC)
Sigma-Aldrich
Sacarosa, ≥99.5% (GC), BioXtra
Sigma-Aldrich
Sacarosa, BioUltra, for molecular biology, ≥99.5% (HPLC)
USP
Sacarosa, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
L-histidina monohydrochloride monohydrate, ≥99.0% (AT)
Sigma-Aldrich
Sacarosa, ≥99.5% (GC), BioReagent, suitable for cell culture, suitable for insect cell culture
Sigma-Aldrich
L-histidina monohydrochloride monohydrate, from non-animal source, meets EP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
Sacarosa, ≥99.5% (GC)
Sigma-Aldrich
L-histidina monohydrochloride monohydrate, ≥98% (HPLC)
Sigma-Aldrich
Sacarosa, ≥99.5% (GC), Grade II, suitable for plant cell culture
Sigma-Aldrich
Sacarosa, Grade I, ≥99% (GC), suitable for plant cell culture
Supelco
Sacarosa, Pharmaceutical Secondary Standard; Certified Reference Material
SAFC
L-histidina monohydrochloride monohydrate
Sigma-Aldrich
Sacarosa, meets USP testing specifications
Sigma-Aldrich
Sacarosa, ACS reagent
Millipore
Sacarosa, suitable for microbiology, ACS reagent, ≥99.0%
Sigma-Aldrich
Sacarosa, puriss., meets analytical specification of Ph. Eur., BP, NF
Sigma-Aldrich
Sacarosa, JIS special grade
Supelco
Sacarosa, analytical standard, for enzymatic assay kit SCA20
Sacarosa, European Pharmacopoeia (EP) Reference Standard
L-histidina monohydrochloride monohydrate, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Sacarosa, SAJ first grade