Documentos clave

RAD121

radiello Triangular Support Plate

pk of 20

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41104008
NACRES:
NB.24
En este momento no podemos mostrarle ni los precios ni la disponibilidad

packaging

pk of 20

manufacturer/tradename

Radiello Code 121

technique(s)

passive air sampling: suitable

application(s)

air monitoring
environmental
industrial hygiene

General description

A radiello diffusive sampler consists of 3 parts: the diffusive body, the adsorbent tube, and the triangular support plate. For personal air sampling, a vertical adapter can be installed. The adsorbent cartridge is removed from its glass or plastic storage tube and is inserted into the diffusive body. This is then threaded onto the triangular support plate in order to place the sampler in its sampling position.
The triangular support plate acts as both a closure and means of suspension for the Radiello diffusive body and cartridge adsorbent during passive air sampling. Each support plate is threaded for easy diffusive body attachment. Each plate includes a clip and transparent adhesive pocket to hold the Radiello barcode label.

Legal Information

radiello is a trademark of Institi Clinici Scientifici Maugeri

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Isabel M Morales Terrés et al.
Journal of environmental management, 91(12), 2754-2762 (2010-09-03)
This paper describes a novel methodology for evaluating the extent to which petrol stations affect their surroundings. The method is based on the fact that the ratio of the concentrations of aliphatic and aromatic hydrocarbon pollutants in the air of
Study of the dispersion of VOCs emitted by a municipal solid waste landfill
Chiriac, R., et al.
Atmospheric Environment, 43 (11), 1926-1931 (2009)
Benoît Oury et al.
Journal of occupational and environmental hygiene, 3(10), 547-557 (2006-08-16)
Diffusive sampling is particularly suited to determine time-weighted average volatile organic compound (VOC) concentration in occupational hygiene and environmental air monitoring. The purpose of this study was to measure the sampling rate variation of four different samplers in a special
P Bruno et al.
Waste management (New York, N.Y.), 27(4), 539-544 (2006-05-23)
Nuisance caused by odors is one of the most important problems for waste management plants. To control an odor nuisance, it must first be quantified. The analytical difficulties in odor measurements are related to the high number of volatile components
Francesc A Esteve-Turrillas et al.
Journal of chromatography. A, 1216(48), 8549-8556 (2009-10-27)
A new procedure for the passive sampling in air of benzene, toluene, ethylbenzene and xylene isomers (BTEX) is proposed. A low-density polyethylene layflat tube filled with a mixture of solid phases provided a high versatility tool for the sampling of

Artículos

radiello® Diffusive Air Sampling Application - Ammonia

radiello® Diffusive Air Sampling Application - Ammonia

radiello® Diffusive Air Sampling Application - Hydrogen Sulfide

radiello® Diffusive Air Sampling Application - Hydrogen Sulfide

Ver todo

Questions

  1. what type of Radiello sampler can be used for ENVIRONMENTAL monitoring of Benzene toluene and xylene (BTX) in petrol stations? Where is the best location to place the sampler to assess BTX in ambient air in petrol station

    1 answer
    1. Two ready-to-use starter kits are available for environmental VOC/BTEX sampling. For chemical desorption techniques, the sampler kit is available under Product No. RAD130S. This kit includes 2 RAD130 adsorbing cartridges and barcode labels, 1 RAD120 white diffusive body, 1 RAD121 triangular support plate, and an instruction sheet. Each of the kit components is available separately.

      For thermal desorption techniques, the sampler kit is available under Product No. RAD145S. This kit includes 2 RAD145 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, and an instruction sheet. Similarly, each of the kit components is available separately.

      For outdoor sampling, an outdoor shelter is available under Product No. RAD196. This shelter is designed to house and protect the sampler(s) from the elements. The outdoor shelter can be mounted on any vertical pole near the sampling site, including lamp posts, traffic lights, and telephone poles of various diameters. Spare mounting strips are available under Product No. RAD198.

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico