568520-U
Discovery® HS C18 (5 µm) HPLC Columns
L × I.D. 5 cm × 4.6 mm, HPLC Column
About This Item
Productos recomendados
product name
Columna para HPLC Discovery® HS C18, 5 μm particle size, L × I.D. 5 cm × 4.6 mm
material
stainless steel column
Quality Level
agency
suitable for USP L1
product line
Discovery®
feature
endcapped
manufacturer/tradename
Discovery®
packaging
1 ea of
extent of labeling
20% Carbon loading
parameter
≤70 °C temp. range
400 bar pressure (5801 psi)
technique(s)
HPLC: suitable
LC/MS: suitable
L × I.D.
5 cm × 4.6 mm
surface area
300 m2/g
surface coverage
3.2 μmol/m2
impurities
<10 ppm metals
matrix
silica gel, high purity, spherical particle platform
fully porous particle
matrix active group
C18 (octadecyl) phase
particle size
5 μm
pore size
120 Å
operating pH range
2-8
application(s)
food and beverages
separation technique
reversed phase
¿Está buscando productos similares? Visita Guía de comparación de productos
Categorías relacionadas
Features and Benefits
- Stable, low bleed for LC-MS applications
- Scalable from analytical to preparatory
- Highly stable to ensure excellent run-to-run and lot-to-lot repducibility
- Higher hydrophobicity for better resolution of difficult analytes
Legal Information
Application
guard cartridge
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Protocolos
Using the method described in this report, an average absolute recovery and RSD value of 99.86 ± 6.99% (n=6) was observed, to determine an average of 1.02% hydrocortisone in topical cream.
Using the method described in this report, an average absolute recovery and RSD value of 99.86 ± 6.99% (n=6) was observed, to determine an average of 1.02% hydrocortisone in topical cream.
Using the method described in this report, an average absolute recovery and RSD value of 99.86 ± 6.99% (n=6) was observed, to determine an average of 1.02% hydrocortisone in topical cream.
Using the method described in this report, an average absolute recovery and RSD value of 99.86 ± 6.99% (n=6) was observed, to determine an average of 1.02% hydrocortisone in topical cream.
Contenido relacionado
HPLC DiscoveryBIO HS C18 products. Available in 3µm, 5µm and 10µm particle sizes.
Chromatograms
application for SPE, application for HPLCNuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico