Saltar al contenido
Merck

PROTSIL2

Sigma-Aldrich

ProteoSilver Plus Silver Stain Kit

Sinónimos:

protein stain, silver stain

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41105322
NACRES:
NA.32

usage

 kit sufficient for 25 mini-gels (10 × 10 cm)

Quality Level

technique(s)

protein staining: suitable

storage temp.

20-25°C

General description

Conveniently packaged, extremely stable, and highly sensitive, ProteoSilver Plus Silver Stain Kit is an ideal product for any protein scientist. Similar to ProteoSilver (PROTSIL1), this kit contains prepared solutions of silver staining reagents along with detailed instructions to achieve optimal results. With a detection limit of 0.1 ng/mm2 of protein (BSA) and an extremely low background, ProteoSilver Plus leads to superior detection of low abundance proteins.
ProteoSilver Plus is also MALDI-MS compatible and does not contain glutaraldehyde, which crosslinks lysine residues, resulting in inaccurate spectra. ProteoSilver Plus Silver Stain Kit contains two additional reagents for destaining an excised protein spot, for those wishing to perform further characterization through tryptic digestion and MALDI-MS analysis.

Application

ProteoSilver Silver Stain Kit has been used for staining of the gels for visualizing proteins. It has also been used for destaining of the protein of interest using destainer provided in the kit for mass spectroscopic analysis.

Features and Benefits

  • Premixed and preweighed solutions reduce time and cost of purchasing and preparing individual components
  • Optimized protocols help establish conditions for best results
  • High sensitivity and low background ensure very low abundance proteins can be detected and resolved from other proteins
  • MALDI Compatible - Protein spots of interest can be further characterized by mass spectrometry
  • Room Temperature Stability allows easy and convenient storage

Legal Information

ProteoSilver is a trademark of Sigma-Aldrich Co. LLC
SIGMA-ALDRICH is a registered trademark of Merck KGaA, Darmstadt, Germany

signalword

Danger

Hazard Classifications

Acute Tox. 2 Inhalation - Acute Tox. 3 Dermal - Acute Tox. 3 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 1B - Eye Dam. 1 - Met. Corr. 1 - Muta. 2 - Repr. 1B - Skin Corr. 1A - Skin Sens. 1 - STOT SE 2 - STOT SE 3

target_organs

Eyes,Central nervous system, Respiratory system

Storage Class

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

wgk_germany

WGK 3

flash_point_f

149.0 °F - closed cup

flash_point_c

65 °C - closed cup


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Slide 1 of 1

1 of 1

Slovénie Pyndiah et al.
Molecular & cellular proteomics : MCP, 6(2), 193-206 (2006-11-10)
The study of protein interactions constitutes an important domain to understand the physiology and pathogenesis of microorganisms. The two-dimensional blue native/SDS-PAGE was initially reported to analyze membrane protein complexes. In this study, both cytoplasmic and membrane complexes of a bacterium
Peeping into human renal calcium oxalate stone matrix: characterization of novel proteins involved in the intricate mechanism of urolithiasis.
Aggarwal KP, et al.
PLoS ONE, 8, e69916-e69916 (2013)
Cédric Bernarde et al.
Molecular & cellular proteomics : MCP, 9(12), 2796-2826 (2010-07-09)
Helicobacter pylori infection plays a causal role in the development of gastric mucosa-associated lymphoid tissue (MALT) lymphoma (LG-MALT) and duodenal ulcer (DU). Although many virulence factors have been associated with DU, many questions remain unanswered regarding the evolution of the
Effect of biomolecules from human renal matrix of calcium oxalate monohydrate (CaOx) stones on in vitro calcium phosphate crystallization.
Pathak P, et al.
International Brazilian Journal of Urology : Official Journal of the Brazilian Society of Urology, 36, 621-628 (2010)
2D map of proteins from human renal stone matrix and evaluation of their effect on oxalate induced renal tubular epithelial cell injury.
Aggarwal KP, et al.
International Brazilian Journal of Urology : Official Journal of the Brazilian Society of Urology, 39, 128-136 (2013)

Artículos

Sigma offers EZBlue™ and ProteoSilver™ reagents for protein visualization, suitable for proteomics and traditional PAGE formats.

Sigma offers EZBlue™ and ProteoSilver™ reagents for protein visualization, suitable for proteomics and traditional PAGE formats.

Sigma offers EZBlue™ and ProteoSilver™ reagents for protein visualization, suitable for proteomics and traditional PAGE formats.

Sigma offers EZBlue™ and ProteoSilver™ reagents for protein visualization, suitable for proteomics and traditional PAGE formats.

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico