Saltar al contenido
Merck

A8511

Sigma-Aldrich

Luminol

≥97% (HPLC)

Sinónimos:

3-Aminophthalhydrazide, 5-Amino-2,3-dihydro-1,4-phthalazinedione

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C8H7N3O2
Número de CAS:
Peso molecular:
177.16
Beilstein:
383929
Número CE:
Número MDL:
Código UNSPSC:
12352204
ID de la sustancia en PubChem:
NACRES:
NA.83

Nivel de calidad

Ensayo

≥97% (HPLC)

Formulario

powder or chunks

mp

>300 °C (lit.)

solubilidad

DMSO: 50 mg/mL, clear to slightly hazy

cadena SMILES

Nc1cccc2C(=O)NNC(=O)c12

InChI

1S/C8H7N3O2/c9-5-3-1-2-4-6(5)8(13)11-10-7(4)12/h1-3H,9H2,(H,10,12)(H,11,13)

Clave InChI

HWYHZTIRURJOHG-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Luminol is a chemiluminescent compound, which belongs to the class of cyclic acyl hydrazides. It exhibits chemiluminescence, when oxidized by oxidizing agents. Luminol may be associated with nausea, vomiting and mucosa irritation in eyes and skin.

Aplicación

Luminol has been used in chemiluminescence assay.

Características y beneficios

Used for chemiluminescence analysis of, for example, metal cations, blood, and glucococorticoids.

Código de clase de almacenamiento

11 - Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable

Equipo de protección personal

dust mask type N95 (US), Eyeshields, Gloves


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Reference values of reactive oxygen species in seminal ejaculates using chemiluminescence assay
Agarwal A, et al.
Journal of Assisted Reproduction and Genetics, 32(12), 1721-1729 (2015)
Luminol-based chemiluminescent signals: clinical and non-clinical application and future uses
Khan P, et al.
Applied Biochemistry and Biotechnology, 173(2), 333-355 (2014)
Christophe A Marquette et al.
Analytical and bioanalytical chemistry, 385(3), 546-554 (2006-05-23)
This critical review discusses the results published between 2000 and 2005 on the development of analytical systems based on the luminol chemiluminescent and electrochemiluminescent reactions. An increasing number of non-specific detection systems based on the enhancing, inhibiting or catalysing effect
Anna Sintsova et al.
PLoS pathogens, 10(9), e1004341-e1004341 (2014-09-05)
An overwhelming neutrophil-driven response causes both acute symptoms and the lasting sequelae that result from infection with Neisseria gonorrhoeae. Neutrophils undergo an aggressive opsonin-independent response to N. gonorrhoeae, driven by the innate decoy receptor CEACAM3. CEACAM3 is exclusively expressed by
Fuan Wang et al.
Chemistry (Weinheim an der Bergstrasse, Germany), 18(50), 16030-16036 (2012-10-20)
The Cu(2+)-dependent ligation DNAzyme is implemented as a biocatalyst for the colorimetric or chemiluminescence detection of Cu(2+) ions, Hg(2+) ions, or cocaine. These sensing platforms are based on the structural tailoring of the sequence of the Cu(2+)-dependent ligation DNAzyme for

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico