Saltar al contenido
Merck

S9625

Sigma-Aldrich

Cloruro de sodio

ReagentPlus®, ≥99%

Sinónimos:

Halita, sal de roca, NaCl

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
NaCl
Número de CAS:
Peso molecular:
58.44
Beilstein:
3534976
Número CE:
Número MDL:
Código UNSPSC:
12352302
ID de la sustancia en PubChem:
NACRES:
NA.21
Ensayo:
≥99%
Formulario:
powder or crystals
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Agency

suitable for GB 5009.253-2016

Nivel de calidad

presión de vapor

1.33 hPa ( 865 °C)

Línea del producto

ReagentPlus®

Ensayo

≥99%

Formulario

powder or crystals

pH

7

mp

801 °C (lit.)

cadena SMILES

[Na+].[Cl-]

InChI

1S/ClH.Na/h1H;/q;+1/p-1

Clave InChI

FAPWRFPIFSIZLT-UHFFFAOYSA-M

¿Está buscando productos similares? Visita Guía de comparación de productos

Aplicación

El cloruro de sodio se puede utilizar como:      
  • Plantilla para sintetizar nanoláminas de silicio en 2D utilizando ortosilicato de tetraetilo (TEOS) como fuente de sílice. La gran superficie del NaCl promueve la formación de nanoláminas de SiO2 de área grande a través de un proceso de autoensamblaje.      
  • Plantilla para preparar nanocubos huecos de dióxido de estaño (SnO2), que son aplicables como materiales anódicos para baterías de iones de litio.
  • Un soporte catalizador en la síntesis a gran escala de nanofibras de carbono utilizando oxalatos metálicos como catalizadores mediante un método de deposición química de vapor.

Características y beneficios

El NaCl es:      
  • Muy hidrosoluble y rentable.      
  • Fácilmente reciclado a través de un proceso de recristalización.

Información legal

ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany
Redi-Dri is a trademark of Sigma-Aldrich Co. LLC

Código de clase de almacenamiento

13 - Non Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 1

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Kathryn P Trogden et al.
Current biology : CB, 29(14), 2339-2350 (2019-07-16)
The microtubule (MT) network is an essential regulator of insulin secretion from pancreatic β cells, which is central to blood-sugar homeostasis. We find that when glucose metabolism induces insulin secretion, it also increases formation of Golgi-derived microtubules (GDMTs), notably with
Christopher S Morrow et al.
Cell stem cell, 26(4), 558-568 (2020-02-29)
Maintaining a healthy proteome throughout life is critical for proper somatic stem cell function, but the complexities of the stem cell response to increases in damaged or aggregated proteins remain unclear. Here we demonstrate that adult neural stem cells (NSCs)
Anabel Fernández-Iglesias et al.
Journal of cellular and molecular medicine, 23(2), 877-886 (2018-11-13)
Liver cells isolated from pre-clinical models are essential tools for studying liver (patho)physiology, and also for screening new therapeutic options. We aimed at developing a new antibody-free isolation method able to obtain the four main hepatic cell types (hepatocytes, liver

Questions

1–4 of 4 Questions  
  1. How many 500mg pills come in this bottle?

    1 answer
    1. This product is in powder or crystalline for and not offered in pill format. Unless otherwise stated, this product is intended for research use only. It is not suitable for any other purpose, which includes, but is not limited to, unauthorized commercial use, in vitro diagnostic use, or therapeutic use in humans or animals.

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  4. How much calcium this product contain?

    1 answer
    1. This product is not tested for the presence of calcium. The minimum purity specification is 99.0%. Any calcium present would be in trace amounts. If calcium determination is critical for the intended application, please see the link below for a product that is tested for this element:
      https://www.sigmaaldrich.com/product/mm/106404

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico