Saltar al contenido
Merck
Todas las fotos(4)

Documentos clave

I5500

Sigma-Aldrich

Insulina from bovine pancreas

Insulin from bovine pancreas
1 of 1 reviewers received a sample product or took part in a promotion

≥25 USP units/mg (HPLC), powder

Sinónimos:

Insulin (cattle)

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C254H377N65O75S6
Número de CAS:
Peso molecular:
5733.49
EC Number:
MDL number:
UNSPSC Code:
51183600
NACRES:
NA.31
form:
powder
En este momento no podemos mostrarle ni los precios ni la disponibilidad

form

powder

Quality Level

specific activity

≥25 USP units/mg (HPLC)

impurities

≤0.5 EU/mg endotoxin

solubility

water: 2 mg/mL, clear, colorless (pH: 2)

cation traces

Zn: ≤1.0%

UniProt accession no.

shipped in

ambient

storage temp.

−20°C

InChI key

IXIBAKNTJSCKJM-BUBXBXGNSA-N

Gene Information

cow ... INS(280829)

¿Está buscando productos similares? Visita Guía de comparación de productos

Application


  • Cross-frontal mode: An alternative methodology for Taylor dispersion analysis of monomodal sample.: This research presents a novel methodology for Taylor dispersion analysis, which could be applied to the study of insulin dispersion and its implications in biochemical research (Gouyon et al., 2023).

Biochem/physiol Actions

Hormona polipeptídica bicatenaria producida por las células β de los islotes pancreáticos. Su peso molecular es de ~ 5800 Da) Las cadenas α y β se unen por dos enlaces disulfuro intercatenarios. La cadena α contiene un puente disulfuro intracatenario. La insulina regula la captación, utilización y almacenamiento celulares de glucosa, aminoácidos y ácidos grasos, e inhibe la hidrólisis de glucógeno, proteínas y grasas.

Other Notes

InChI: 1S/C254H377N65O75S6/c1-29-131(24)205(312-192(334)103-256)250(389)317-204(130(22)23)246(385)287-158(74-81-199(344)345)216(355)281-155(70-77-188(260)330)220(359)307-183-116-399-400-117-184-242(381)305-177(110-321)238(377)293-161(87-122(6)7)223(362)294-167(94-139-52-60-145(324)61-53-139)226(365)282-153(68-75-186(258)328)217(356)289-160(86-121(4)5)221(360)284-157(73-80-198(342)343)219(358)301-173(100-189(261)331)233(372)297-169(96-141-56-64-147(326)65-57-141)229(368)308-182(241(380)303-175(253(393)394)102-191(263)333)115-398-396-113-180(212(351)270-106-193(335)277-152(71-78-196(338)339)215(354)280-150(50-41-83-268-254(264)265)210(349)269-107-194(336)278-165(92-137-45-35-31-36-46-137)225(364)296-166(93-138-47-37-32-38-48-138)228(367)298-170(97-142-58-66-148(327)67-59-142)236(375)318-206(135(28)323)251(390)319-84-42-51-185(319)244(383)285-151(49-39-40-82-255)213(352)276-134(27)252(391)392)310-248(387)202(128(18)19)315-234(373)163(89-124(10)11)291-227(366)168(95-140-54-62-146(325)63-55-140)295-222(361)159(85-120(2)3)288-207(346)132(25)274-214(353)156(72-79-197(340)341)286-245(384)201(127(16)17)314-235(374)164(90-125(12)13)292-231(370)172(99-144-105-267-119-273-144)300-237(376)176(109-320)279-195(337)108-271-211(350)179(112-395-397-114-181(309-243(183)382)240(379)275-133(26)208(347)304-178(111-322)239(378)316-203(129(20)21)249(388)311-184)306-224(363)162(88-123(8)9)290-230(369)171(98-143-104-266-118-272-143)299-218(357)154(69-76-187(259)329)283-232(371)174(101-190(262)332)302-247(386)200(126(14)15)313-209(348)149(257)91-136-43-33-30-34-44-136/h30-38,43-48,52-67,104-105,118-135,149-185,200-206,320-327H,29,39-42,49-51,68-103,106-117,255-257H2,1-28H3,(H2,258,328)(H2,259,329)(H2,260,330)(H2,261,331)(H2,262,332)(H2,263,333)(H,266,272)(H,267,273)(H,269,349)(H,270,351)(H,271,350)(H,274,353)(H,275,379)(H,276,352)(H,277,335)(H,278,336)(H,279,337)(H,280,354)(H,281,355)(H,282,365)(H,283,371)(H,284,360)(H,285,383)(H,286,384)(H,287,385)(H,288,346)(H,289,356)(H,290,369)(H,291,366)(H,292,370)(H,293,377)(H,294,362)(H,295,361)(H,296,364)(H,297,372)(H,298,367)(H,299,357)(H,300,376)(H,301,358)(H,302,386)(H,303,380)(H,304,347)(H,305,381)(H,306,363)(H,307,359)(H,308,368)(H,309,382)(H,310,387)(H,311,388)(H,312,334)(H,313,348)(H,314,374)(H,315,373)(H,316,378)(H,317,389)(H,318,375)(H,338,339)(H,340,341)(H,342,343)(H,344,345)(H,391,392)(H,393,394)(H4,264,265,268)/t131-,132-,133-,134-,135+,149-,150-,151-,152-,153-,154-,155-,156-,157-,158-,159-,160-,161-,162-,163-,164-,165-,166-,167-,168-,169-,170-,171-,172-,173-,174-,175-,176-,177-,178-,179-,180-,181-,182-,183-,184-,185-,200-,201-,202-,203-,204-,205-,206-/m0/s1

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Denise Laskowski et al.
Molecular reproduction and development, 85(7), 599-611 (2018-05-11)
Insulin functions as a regulator of metabolism and plays an important role in reproduction. Hyperinsulinemia is often observed in patients with obesity and diabetes type 2 and is known to impair fertility, but the underlying molecular mechanisms are only partly
Mohamed R Ben Khedher et al.
PeerJ, 6, e4166-e4166 (2018-01-16)
Diet-induced obese (DIO) mice were treated for five weeks with sage methanol extract (100 and 400 mg kg After two weeks of treatment, the lower dose of sage MetOH extract decreased blood glucose and plasma insulin levels during an oral glucose
Felix Weis et al.
Nature communications, 9(1), 4420-4420 (2018-10-26)
Understanding the structural biology of the insulin receptor and how it signals is of key importance in the development of insulin analogs to treat diabetes. We report here a cryo-electron microscopy structure of a single insulin bound to a physiologically
Anisha M Hammer et al.
Neoplasia (New York, N.Y.), 19(6), 496-508 (2017-05-16)
The extracellular matrix (ECM) is critical for mammary ductal development and differentiation, but how mammary fibroblasts regulate ECM remodeling remains to be elucidated. Herein, we used a mouse genetic model to activate platelet derived growth factor receptor-alpha (PDGFRα) specifically in
Natalie A Dye et al.
Development (Cambridge, England), 144(23), 4406-4421 (2017-10-19)
Quantitative analysis of the dynamic cellular mechanisms shaping the

Protocolos

Chromatographic technique identifies insulin variants efficiently, aiding in pharmacokinetics.

Chromatographic technique identifies insulin variants efficiently, aiding in pharmacokinetics.

Chromatographic technique identifies insulin variants efficiently, aiding in pharmacokinetics.

Chromatographic technique identifies insulin variants efficiently, aiding in pharmacokinetics.

Questions

1–9 of 9 Questions  
  1. How do you determine the potency that is given in the CoA. Is the material qualified against another Insulin bovine standard (primary standard, e.g. Insulin (bovine) CRS)?

    1 answer
    1. The potency of this product is determined by the USP HPLC method and calculated based on the HPLC area %. The material is tested against the USP human insulin standard, product 1342106.

      Helpful?

  2. How should stock solutions of item I5500, Insulin from bovine pancreas be stored?

    1 answer
    1. Stock vials of bovine insulin should be stored at -20°C in a non-frost-free freeze.

      Helpful?

  3. Is Insulin product (I5500) a lyophilization powder?

    1 answer
    1. Yes, this product is lyophilized

      Helpful?

  4. How many units of insulin are present in my vial of Product I5500, Insulin from bovine pancreas?

    1 answer
    1. Product No. I5500 has a specification of not less than 27 USP units/mg.  The exact value for the product received can be found the on lot-specific Certificate of Analysis.

      Helpful?

  5. What can be used to make a solution of insulin?

    1 answer
    1. Insulin is soluble in dilute acids and alkalis. The solubility of insulin is tested at 2 mg/mL in water (acidified to pH 2 with hydrochloric acid). One can also use 1 mL of water acidified to pH 2 with 10 μL of glacial acetic acid to dissolve 2 mg of insulin. A 10 mg/mL solution of bovine insulin in 25 mM HEPES at pH 8.2 is offered as Product No. I0516.

      Helpful?

  6. What is the amino acid sequence for insulin?

    1 answer
    1. The sequence and structure of insulin can be found on the product information sheet (under Documents, above).

      Helpful?

  7. How can I store the insulin solution?  How long?

    1 answer
    1. The USP recommends that solutions of insulin be stored at 2-8°C. It is not recommended to freeze solutions of insulin, as it can aggregate. Sterile solutions should be stable for at least 1 year at 2-8°C.

      Helpful?

  8. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  9. What is the comparison between International Units (IU) and USP units for insulin?

    1 answer
    1. The international unit (IU) of insulin is based on the International Standard Preparation of Bioassay (1958). The standard preparation is a mixture of 52% bovine and 48% porcine insulin, containing 24 units/mg. Reference: Martindale: The Extra Pharmacopoeia, 29th ed., p. 392. High purity bovine pancreatic insulin typically assays at approximately 27 USP units per mg. So the IU and USP unit are not identical, but they are approximately 1:1.

      Helpful?

Reviews

1 of 1 reviewers received a sample product or took part in a promotion

Active Filters

    • Review 1
    • Vote 1
    5 out of 5 stars.

    Good

    Performed as expected. No problems whatsoever. Fine.

    Helpful?

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico