RMNPMAG-83K
MILLIPLEX® Rat/Mouse Neuropeptide Magnetic Bead Panel - Neuroscience Multiplex Assay
The analytes available for this multiplex kit are: α-MSH, β-Endorphin, Neurotensin, Oxytocin, Substance P.
About This Item
Productos recomendados
Quality Level
species reactivity
mouse, rat
manufacturer/tradename
Milliplex®
assay range
accuracy: 107-135%
(Rat)
standard curve range: 14-100,000 pg/mL
(Oxytocin)
standard curve range: 27-20,000 pg/mL
(Neurotensin)
standard curve range: 3-2,000 pg/mL
(Substance P)
standard curve range: 41-30,000 pg/mL
(α-MSH)
standard curve range: 69-50,000 pg/mL
(β-Endorphine)
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex xMAP)
shipped in
wet ice
General description
An important note about this panel is that the samples may be extracted using either the acetonitrile precipitation technique or the Waters 96-well HLB extraction plate. Please refer to the protocol for more information on both methods. The necessary components to perform the extractions are not included with the kit.
The central nervous system is a complex environment consisting of billions of neurons as well as glial support cells. These neurons use many different chemical signals to communicate information, including neurotransmitters, cannabinoids, peptides, and gases such as nitric oxide. Neuropeptides are secreted primarily from the central and peripheral nervous systems, exerting a broad spectrum of biological functions that includes the regulation of metabolism, reproduction, and immunity.
Panel Type: Neuroscience
Application
- Analytes: α-MSH, β-Endorphin, Neurotensin, Oxytocin, Substance P.
- Recommended Sample type: serum, plasma, CSF, and tissue culture
- Recommended Sample dilution: This assay requires 50 μL extracted serum or plasma sample per well or 50 μL neat CSF or culture media per well
- Assay Run Time: Overnight
- NOTE: this is a competitive assay.
Features and Benefits
Other Notes
Legal Information
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Storage Class
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico