Measurement of analytes in urine typically requires either a 24-hour urine collection or a second morning void collection. The analyte value is normalized against creatinine, meaning that the analyte is expressed as units/mg of creatinine.
MCYTOMAG-70K
Panel de microesferas magnéticas de citocinas/quimiocinas de ratón MILLIPLEX® - Ensayo múltiple de inmunología
Simultaneously analyze multiple cytokine and chemokine biomarkers with Bead-Based Multiplex Assays using the Luminex technology, in mouse serum, plasma and cell culture samples.
Sinónimos:
Luminex® Mouse cytokine immunoassay, Millipore Mouse cytokine immunoassay, Mouse cytokine Multiplex Assay
About This Item
Productos recomendados
Nivel de calidad
reactividad de especies
mouse
fabricante / nombre comercial
Milliplex®
assay range
accuracy: 85-107%
standard curve range: 3.2-10,000 pg/mL
técnicas
multiplexing: suitable
método de detección
fluorometric (Luminex xMAP)
Condiciones de envío
wet ice
Descripción general
- Opciones más flexibles de placa y lavadoras la de placa
- Mejor rendimiento con muestras de suero o plasma turbias
- Resultados de los análisis equivalentes a los obtenidos sin microesferas
- El lavado automatizado evita muchos de los problemas asociados con el lavado con filtración al vacío
El panel de citocinas/quimiocinas de ratón MILLIPLEX® le permite concentrarse en el potencial terapéutico de las citocinas, así como en la modulación de la expresión de las citocinas. Junto con la plataforma Luminex® xMAP® en un formato de microesfera, obtendrá la ventaja de la velocidad y la sensibilidad ideales, lo que permite la detección cuantitativa múltiple de docenas de analitos simultáneamente y a su vez puede mejorar considerablemente la productividad.
Tipo de panel: Citocinas/quimiocinas
Aplicación
- Analitos: G-CSF, GM-CSF, IFN-γ, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-9, IL-10, IL-12 (p40), IL-12 (p70), IL-13, IL-15, IL-17, IP-10, KC, LIF, LIX, MCP-1, M-CSF, MIG, MIP-1α, MIP-1β, MIP-2, RANTES, TNF-α, VEGF, Eotaxina/CCL11
Características y beneficios
Otras notas
Información legal
Palabra de señalización
Danger
Frases de peligro
Consejos de prudencia
Clasificaciones de peligro
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Órganos de actuación
Respiratory Tract
Código de clase de almacenamiento
10 - Combustible liquids
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Contenido relacionado
Learn how immunoassays are used in cosmetics and personal care research to discover potential harmful effects of cosmetics products, and assess markers of inflammation, sensitization, aging, and tissue regeneration among others.
Learn how immunoassays are used in cosmetics and personal care research to discover potential harmful effects of cosmetics products, and assess markers of inflammation, sensitization, aging, and tissue regeneration among others.
Learn how immunoassays are used in cosmetics and personal care research to discover potential harmful effects of cosmetics products, and assess markers of inflammation, sensitization, aging, and tissue regeneration among others.
Learn how immunoassays are used in cosmetics and personal care research to discover potential harmful effects of cosmetics products, and assess markers of inflammation, sensitization, aging, and tissue regeneration among others.
-
Can the Cytokine Milliplex kits be used to measure cytokines in urine samples?
1 answer-
Helpful?
-
-
How should data that are below the detection limit be analyzed in the case of a Cytokine Milliplex kit where there are quite a few samples below the detection limit, causing the distribution to be non-normal? Should these data be input as "0.00" or should the lower detection limit be used as the value?
1 answer-
Most users will report the values as less than the manufacturer's limit of detection and then provide the sensitivity of each analyte in the Methods. Here are a couple of references as an example:
- Impact of telmisartan on the inflammatory state in patients with coronary atherosclerosis--influence on IP-10, TNF-α and MCP-1. Klinghammer L, Urschel K, Cicha I, Lewczuk P, Raaz-Schrauder D, Achenbach S, Garlichs CD. Cytokine. 2013 May;62(2):290-6.
- Plasma cytokine profiles in HIV-1 infected patients developing neuropathic symptoms shortly after commencing antiretroviral therapy: a case-control study. Van der Watt JJ, Wilkinson KA, Wilkinson RJ, Heckmann JM. BMC Infect Dis. 2014 Feb 10;14(1):71.
Helpful?
-
-
Can you confirm whether the detection antibodies of a multiplex kit are azide-free?
1 answer-
The detection antibody cocktail is not azide-free.
Helpful?
-
-
Which chemicals can cause bleaching of the Luminex beads?
1 answer-
The following solvents should not be used with Luminex microspheres as they will affect the classification dyes in the microspheres: Aromatic Hydrocarbons (Benzene, Toluene, Xylene, Ethylbenzene), Chlorinated aliphatic Hydrocarbons (Methylene chloride, Chloroform, Carbon tetrachloride), and Others (Pyridine, Dioxane, Dimethylformamide, Methyl ethyl ketone, Cyclohexanone, Tetrahydrofuran, N-butyl phthalate, Methyl phthalate, Ethyl phthalate, Tetrahydrofurfuryl alcohol, Ethyl acetate, Butyl acetate, 1-nitro-propane, Carbon disulfide, Tributyl phosphate, Cyclohexane, Methylcyclohexane, Ethylcyclohexane, Acetone, DMSO).
High salt concentrations will also affect the classification of the microspheres on the Luminex 200 and FLEX 3D; as the salt concentration of the buffer increases, the microspheres will tend to spread out the bead map. High salt buffers (6X SSC, >0.2M NaCL) should be diluted or exchanged prior to analysis as they can interfere with microsphere classification.
Helpful?
-
-
Do you have guidelines available for preparing human and mouse adipose tissue for use in the Milliplex kits to measure cytokine levels?
1 answer-
Our kits have not been validated for use with adipose tissue, although they can be used with various biological samples. Below are the guidelines for preparing adipose tissue:
- Approximately 4 g of adipose tissue from each subject should be homogenized in 16 ml of ice-cold homogenization buffer containing 10% glycerol, 150 mM NaCl, 2 mM EDTA, 1 mM PMSF, 25 mM benzamidine, 10 µM leupeptin, 2.5 µmol/liter pepstatin A, and 50 U/ml aprotinin in 10 mM Tris-HCl (pH 7.0), using a Polytron (Brinkmann Instruments, Inc., Westbury NY) with four up/down strokes at Setting No. 3.
- The crude homogenate should be centrifuged at 3,000 x g for 15 min, and the fat cake should be discarded. The homogenate should then be centrifuged again at 15,000 x g for 20 min at 4°C.
- The supernatant should be stored in aliquots at -80°C.The details provided are sourced from the Journal of Clinical Endocrinology & Metabolism Vol. 86, No. 12 5973-5980, authored by Xiangdong Wu, Johan Hoffstedt, Wasim Deeb, Reetu Singh, Natalia Sedkova, Assaf Zilbering, Li Zhu, Pauline K. Park, Peter Arner, and Barry J. Goldstein.
Helpful?
-
-
What is the maximum number of samples that can be processed in one plate of the Milliplex Luminex Mouse Cytokine kit (MCYTOMAG-70K)?
1 answer-
The Milliplex Luminex Mouse Cytokine kit (MCYTOMAG-70K) allows for processing 1 plate with 37 unknown samples and duplicates.
Helpful?
-
-
Is IL-18 for mouse available in the Milliplex kits?
1 answer-
IL-18 is available through the Custom Assay program under the Cat# SPRCUS889. It includes concentrated IL-18 Standard, concentrated IL-18 Beads, and concentrated IL-18 Detection Antibody. This can be spiked into MCYTOMAG-70K or MTH17MAG-47K. The IL-18 bead region (63) does not overlap with any regions in these 2 panels.
Helpful?
-
-
Could you provide information about the antibody specificity of IL-12p40 and IL-12p70?
1 answer-
The IL-12p40 antibody captures p40 on IL-12p40, IL-23, and is 30% cross-reactive to IL-12p70. For detection, it binds to p40 monomer, homodimer, and heterodimer, p35/p40. The IL-12p70 antibody, on the other hand, is specific to the p35 subunit and therefore only binds to IL-12p70. For detection, it binds to the p40 monomer, homodimer, and heterodimer.
Helpful?
-
-
Can you confirm or clarify whether the GRO antibody pair used in the Mouse Cytokine Panel 1 is a pan assay or specific to GRO1a?
1 answer-
The GRO antibody in the MCYTOMAG-70K panel is specific to GROa/CXCL1, also known as KC or CINC-1.
Helpful?
-
Active Filters