Saltar al contenido
Merck

662631

Sigma-Aldrich

Poly(styrene-alt-maleic acid) sodium salt solution

13 wt. % in H2O

Sinónimos:

Maleic anhydride-styrene copolymer sodium salt, Styrene-maleic anhydride polymer sodium salt

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
(C16H14Na2O8)n
Número de CAS:
Número MDL:
Código UNSPSC:
12162002
ID de la sustancia en PubChem:
NACRES:
NA.23

mol peso

average Mw 350,000

Nivel de calidad

concentración

13 wt. % in H2O

índice de refracción

n20/D 1.362

densidad

1.070 g/mL at 25 °C

cadena SMILES

[Na+].[Na+].OC(=O)\C=C\C(O)=O.[O-]C(=O)\C=C\C([O-])=O.C=Cc1ccccc1

InChI

1S/C8H8.C4H2O3/c1-2-8-6-4-3-5-7-8;5-3-1-2-4(6)7-3/h2-7H,1H2;1-2H

Clave InChI

WOLATMHLPFJRGC-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Pictogramas

Corrosion

Palabra de señalización

Danger

Frases de peligro

Consejos de prudencia

Clasificaciones de peligro

Eye Dam. 1 - Skin Irrit. 2

Código de clase de almacenamiento

10 - Combustible liquids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

G D Guerra et al.
Journal of biomaterials science. Polymer edition, 4(6), 643-652 (1993-01-01)
The activation of human plasma prekallikrein (PKK) to kallikrein (KK), induced by the contact of blood with foreign materials, is a useful in vitro hemocompatibility test. Kallikrein is easily detected by its reaction with the chromogenic substrate H-D-Pro-Phe-Arg-pNA, which releases
N K Lohiya et al.
International journal of andrology, 23(1), 36-42 (2000-01-13)
The feasibility of a spacing method for contraception, using Styrene Maleic Anhydride (SMA) as a vas occlusive agent, has been assessed in male langur monkeys. The vas deferens of 6 animals were occluded with 60 mg SMA in 120 microL
K Verma et al.
Journal of reproduction and fertility, 63(2), 539-542 (1981-11-01)
An alternate co-polymer of styrene and maleic anhydride was dissolved in dimethylsulphoxide and injected into the vas deferens of rats. The polymer was retained in the vas deferens and the morphological changes detected were confined to the mucosa. When the
N Sethi et al.
Contraception, 42(3), 337-347 (1990-09-01)
A newly developed male contraceptive, styrene maleic anhydride (SMA), was injected in the vas deferens of male rhesus monkeys for safety evaluation at the dose of 100 mg (contraceptive dose, CD), 250 mg (CD x 2.5) and 500 mg (CD
S K Guha et al.
Contraception, 32(1), 109-118 (1985-07-01)
A new male method of contraception by injecting a polymer, styrene-maleic anhydride (SMA), into the lumen of the vas deferens has been studied on rhesus monkeys. The polymer has the dual feature that it can occlude the vas deferens lumen

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico