568899
3-Mercaptophenol
96%
Sinónimos:
3-Hydroxythiophenol
Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización
About This Item
Productos recomendados
Quality Level
assay
96%
refractive index
n20/D >1.6290 (lit.)
bp
242-243 °C (lit.)
mp
16-17 °C (lit.)
density
1.237 g/mL at 25 °C (lit.)
SMILES string
Oc1cccc(S)c1
InChI
1S/C6H6OS/c7-5-2-1-3-6(8)4-5/h1-4,7-8H
InChI key
DOFIAZGYBIBEGI-UHFFFAOYSA-N
Categorías relacionadas
General description
3-mercaptophenol coated cantilevers can be used as formaldehyde sensors since it is highly selective towards formaldehyde and can show highest downward deflection on coming in contact with it.
Application
3-mercaptophenol may be used in the synthesis of the following:
- 4-(3-hydroxyphenylthio)naphthalene-1,2-dione, which shows fluorosence emission
- [C6H4-1-(SPPh2)-3-(OPPh2)], a non-symmetric ligand which can combine with PdCl2 to form a pincer complex
signalword
Danger
hcodes
Hazard Classifications
Eye Dam. 1 - Skin Sens. 1
Storage Class
10 - Combustible liquids
wgk_germany
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
"Microfabricated formaldehyde gas sensors"
Sensors, 9(11), 9196-9215 (2009)
"Fluorescence properties, aluminium ion selective emission changes and self-assemblies of positional isomers of 4-(hydroxyphenylthio) naphthalene-1, 2-diones"
Dyes and Pigments, 110, 56- 66 (2014)
"Detection of formaldehyde vapor using mercaptophenol-coated piezoresistive cantilevers"
Sensors and Actuators B, Chemical, 126(2), 522-526 (2007)
"Synthesis of a novel non-symmetric Pd (II) phosphinito?thiophosphinito PSCOP pincer compound"
"Synthesis of a novel non-symmetric Pd (II) phosphinito?thiophosphinito PSCOP pincer compound"
"Synthesis of a novel non-symmetric Pd (II) phosphinito?thiophosphinito PSCOP pincer compound"
Inorgorganica Chimica Acta, 363(6), 1306-1310 (2010)
Advanced science (Weinheim, Baden-Wurttemberg, Germany), 7(10), 1903730-1903730 (2020-05-23)
Reliable monitoring of metabolites in biofluids is critical for diagnosis, treatment, and long-term management of various diseases. Although widely used, existing enzymatic metabolite assays face challenges in clinical practice primarily due to the susceptibility of enzyme activity to external conditions
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico