Saltar al contenido
Merck

374350

Sigma-Aldrich

Tridodecylmethylammonium iodide

97%

Sinónimos:

Methyltridodecylammonium iodide

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
[CH3(CH2)11]3N(I)CH3
Número de CAS:
Peso molecular:
663.93
Beilstein/REAXYS Number:
4260774
MDL number:
UNSPSC Code:
12352116
PubChem Substance ID:
NACRES:
NA.22

Quality Level

assay

97%

mp

106-107 °C (lit.)

SMILES string

[I-].CCCCCCCCCCCC[N+](C)(CCCCCCCCCCCC)CCCCCCCCCCCC

InChI

1S/C37H78N.HI/c1-5-8-11-14-17-20-23-26-29-32-35-38(4,36-33-30-27-24-21-18-15-12-9-6-2)37-34-31-28-25-22-19-16-13-10-7-3;/h5-37H2,1-4H3;1H/q+1;/p-1

InChI key

JRLISGAUAJZAGL-UHFFFAOYSA-M

¿Está buscando productos similares? Visita Guía de comparación de productos

Application

Tridodecylmethylammonium iodide (3C12MAI) can be used:
  • As a triple-chained cationic surfactant.
  • to prepapre glucose oxidase enzyme immobilized iodide electrode for the detection of glucose concentration.
  • As a cationic phase-transfer catalyst in the oxidation of hydrocarbons by O2.

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Preparation and application of a new glucose sensor based on iodide ion selective electrode
K Sukru, et al.
Talanta, 65(1), 87-91 (2005)
The role of onium salts in the oxidation of hydrocarbons by O 2 catalysed by cationic phase-transfer reagents
Csanyi L, et al.
Physical Chemistry Chemical Physics, 2(17), 3801-3805 (2000)
Effect of cyclodextrins on the stability of bilayer: A novel electrophoretic approach
Zandkarimi M, et al.
Journal of Liquid Chromatography and Related Technologies, 37(17), 2433-2443 (2014)
Youngjea Kang et al.
Analytical chemistry, 83(10), 3957-3962 (2011-04-20)
Contamination of heparin with oversulfated chondroitin sulfate (OSCS) became a matter of grave concern in the medical field after many fatal responses to OSCS tainted heparin products occurred during the 2007-2008 period. Even though standard lab-based analytical techniques such as
H Pärsson et al.
Cardiovascular surgery (London, England), 2(2), 242-248 (1994-04-01)
The healing characteristics of polymer-coated Dacron grafts with or without heparin-bonding and collagen-coated Dacron grafts are compared with standard knitted Dacron grafts by implanting eight of each graft into pig iliac arteries. The grafts were implanted at random bilaterally with

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico