295361
Hexafluoroethane
≥98%
Sinónimos:
CFC-116, Perfluoroethane
Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización
About This Item
Productos recomendados
vapor density
4.7 (vs air)
Quality Level
vapor pressure
430 psi ( 21 °C)
assay
≥98%
bp
−78 °C (lit.)
mp
−100 °C (lit.)
SMILES string
FC(F)(F)C(F)(F)F
InChI
1S/C2F6/c3-1(4,5)2(6,7)8
InChI key
WMIYKQLTONQJES-UHFFFAOYSA-N
Packaging
Supplied in a carbon steel lecture bottle with a CGA180M/CGA110F needle valve installed.
Compatible with the following:
Compatible with the following:
- Aldrich® lecture-bottle station systems
- Aldrich® lecture-bottle gas regulators
Other Notes
See Technical Information Bulletin AL-151 Gas Regulators: Selection, Installation, and Operation
Legal Information
Aldrich is a registered trademark of Sigma-Aldrich Co. LLC
Hose barb
Referencia del producto
Descripción
Precios
Optional
Referencia del producto
Descripción
Precios
Purge valve
Referencia del producto
Descripción
Precios
also commonly purchased with this product
Referencia del producto
Descripción
Precios
control valve
regulator
signalword
Warning
hcodes
pcodes
Hazard Classifications
Press. Gas Liquefied gas
Storage Class
2A - Gases
wgk_germany
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, multi-purpose combination respirator cartridge (US)
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Ophthalmology, 120(3), 629-634 (2012-12-06)
To study macular hole (MH) surgery in terms of baseline demographics, intraoperative complications, post-vitrectomy cataract, reoperation, and visual outcome. National Ophthalmology Database study. A total of 1078 eyes from 1045 patients undergoing primary MH surgery. Participating centers prospectively collected clinical
Ophthalmology, 118(1), 150-155 (2010-11-03)
To establish whether the success rate of surgery for small idiopathic macular holes (diameter, ≤ 400 μm) is significantly reduced if facedown positioning is replaced by simply taking care to avoid the supine position. Randomized, controlled, parallel-assignment, open-label, interventional, multicenter
American journal of ophthalmology, 146(1), 128-134 (2008-04-29)
To compare two therapeutic modalities on anatomic and functional results after idiopathic macular hole (MH) surgery: seated vs face-down position. Multicenter, prospective, randomized trial. University Hospital Dijon and University Hospital Nancy. One hundred and forty-four patients (150 eyes) were enrolled
Archivos de la Sociedad Espanola de Oftalmologia, 86(9), 295-299 (2011-09-07)
A twenty three year old woman was diagnosed of a morning glory papillary anomaly, then with normal visual acuity (VA). Nine years later, the VA decreased to 0.4, secondary to a serous macular detachment, confirmed by optical coherence tomography (OCT).
Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye, 42(3), 229-233 (2011-05-14)
To determine posterior capsule opacification (PCO) rate and identify contributory factors in a series of patients undergoing combined 23-gauge transconjunctival phacovitrectomy. Retrospective data on 221 consecutive patients operated on by a single senior surgeon using a standard technique were collected
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico