跳转至内容
Merck
  • Liquid chromatography coupled to quadrupole-time of flight tandem mass spectrometry based quantitative structure-retention relationships of amino acid analogues derivatized via n-propyl chloroformate mediated reaction.

Liquid chromatography coupled to quadrupole-time of flight tandem mass spectrometry based quantitative structure-retention relationships of amino acid analogues derivatized via n-propyl chloroformate mediated reaction.

Journal of chromatography. A (2015-06-06)
Nikolaos Kritikos, Anna Tsantili-Kakoulidou, Yannis L Loukas, Yannis Dotsikas
摘要

In the current study, quantitative structure-retention relationships (QSRR) were constructed based on data obtained by a LC-(ESI)-QTOF-MS/MS method for the determination of amino acid analogues, following their derivatization via chloroformate esters. Molecules were derivatized via n-propyl chloroformate/n-propanol mediated reaction. Derivatives were acquired through a liquid-liquid extraction procedure. Chromatographic separation is based on gradient elution using methanol/water mixtures from a 70/30% composition to an 85/15% final one, maintaining a constant rate of change. The group of examined molecules was diverse, including mainly α-amino acids, yet also β- and γ-amino acids, γ-amino acid analogues, decarboxylated and phosphorylated analogues and dipeptides. Projection to latent structures (PLS) method was selected for the formation of QSRRs, resulting in a total of three PLS models with high cross-validated coefficients of determination Q(2)Y. For this reason, molecular structures were previously described through the use of descriptors. Through stratified random sampling procedures, 57 compounds were split to a training set and a test set. Model creation was based on multiple criteria including principal component significance and eigenvalue, variable importance, form of residuals, etc. Validation was based on statistical metrics Rpred(2),QextF2(2),QextF3(2) for the test set and Roy's metrics rm(Av)(2) and rm(δ)(2), assessing both predictive stability and internal validity. Based on aforementioned models, simplified equivalent were then created using a multi-linear regression (MLR) method. MLR models were also validated with the same metrics. The suggested models are considered useful for the estimation of retention times of amino acid analogues for a series of applications.

材料
货号
品牌
产品描述

Sigma-Aldrich
氢氧化钠 溶液, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
氢氧化钠 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
甲酸铵, ≥99.995% trace metals basis
Sigma-Aldrich
氢氧化钠 溶液, 0.1 M
Sigma-Aldrich
甲酸铵 溶液, BioUltra, 10 M in H2O
Sigma-Aldrich
甲醇, JIS special grade, ≥99.8%
Sigma-Aldrich
氢氧化钠 溶液, 1 M
Sigma-Aldrich
2-甲基吡啶, 98%
Sigma-Aldrich
氢氧化钠, BioUltra, for luminescence, ≥98.0% (T), pellets
Sigma-Aldrich
氢氧化钠, JIS special grade, ≥96.0%
Sigma-Aldrich
甲醇, SAJ first grade, ≥99.5%
Sigma-Aldrich
2,2,4-三甲基戊烷, JIS special grade
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
1-丙醇, anhydrous, 99.7%
Sigma-Aldrich
2,2,4-三甲基戊烷, anhydrous, 99.8%
Sigma-Aldrich
氢氧化钠, ultra dry, powder or crystals, 99.99% trace metals basis
Sigma-Aldrich
氢氧化钠, SAJ first grade, ≥95.0%
Sigma-Aldrich
1-丙醇, ≥99%, FG
Supelco
甲酸铵 溶液, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
氢氧化钠 溶液, 6 M
Sigma-Aldrich
甲酸, JIS special grade, ≥98.0%
Sigma-Aldrich
甲醇, suitable for HPLC
Sigma-Aldrich
甲醇, SAJ special grade
Sigma-Aldrich
氢氧化钠 溶液, 0.2 M
Sigma-Aldrich
氢氧化钠 溶液, 0.01 M
Sigma-Aldrich
1-丙醇, natural, ≥98%, FG
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, 99.93%
Sigma-Aldrich
氢氧化钠 溶液, 0.05 M
Sigma-Aldrich
甲醇, NMR reference standard