跳转至内容
Merck
  • Linear retention index approach applied to liquid chromatography coupled to triple quadrupole mass spectrometry to determine oxygen heterocyclic compounds at trace level in finished cosmetics.

Linear retention index approach applied to liquid chromatography coupled to triple quadrupole mass spectrometry to determine oxygen heterocyclic compounds at trace level in finished cosmetics.

Journal of chromatography. A (2021-05-27)
Adriana Arigò, Paola Dugo, Francesca Rigano, Luigi Mondello
摘要

In the European Union, cosmetic products are regulated by the Cosmetics Regulation (EC) No. 1223/2009. The Analytical Working Group of the International Fragrance Association (IFRA) suggested that a new sensitive analytical method is needed to determine psoralens in finished cosmetic products. This research provides an HPLC-MS/MS method for the quality control of 20 furocoumarins, 8 coumarins and 7 polymethoxyflavones in cosmetics. Thanks to the high sensitivity of the tandem mass spectrometry detection in Multiple Reaction Monitoring mode, psoralens contained in trace have been quantified in different products. The Limits of Quantifications were in the range 0.3-74 μg L-1. A reliable identification was achieved combining the Linear Retention Index (LRI) system with the MS and MS/MS libraries. In particular, the attribution was based on the spectra similarity filtered by the LRI parameter. The robustness and reproducibility of the LRI approach was demonstrated by the comparison of the HPLC-MS/MS results here reported with those obtained in our previous study, by using an HPLC-PDA system. This method could be taken into account for quality control of furocoumarins in cosmetics, and by the main associations, such as IFRA, for the purpose of issuing new opinions.

材料
货号
品牌
产品描述

Supelco
Ascentis® Express C18, 2.7 μm HPLC 色谱柱, 2.7 μm particle size, L × I.D. 5 cm × 4.6 mm
Supelco
苯乙酮, analytical standard
Supelco
苯丙酮, analytical standard
Supelco
Cnidicin, analytical standard
Oxypeucedanin, phyproof® Reference Substance
Supelco
8-甲氧基补骨脂素, analytical standard
Supelco
5-甲氧基补骨脂素, analytical standard
Supelco
Tetra-O-methylscutellarein, analytical standard
Supelco
橙皮内酯水合物, analytical standard
白当归素, phyproof® Reference Substance
Supelco
佛手柑素, analytical standard
Supelco
Meranzin, analytical standard
Supelco
5-Geranyloxy-7-methoxycoumarin, analytical standard
Isobergapten, phyproof® Reference Substance
Supelco
Cnidilin, analytical standard
Biacangelicol, phyproof® Reference Substance
Phellopterin, phyproof® Reference Substance
三甲沙林, phyproof® Reference Substance
Oxypeucedanin hydrate, phyproof® Reference Substance
Supelco
丁酰苯, analytical standard
5-Demethylnobiletin, phyproof® Reference Substance
Gardenin B, phyproof® Reference Substance
(±)-Heraclenin, phyproof® Reference Substance