23307-U
Columna para GC capilar SP®-5
L × I.D. 50 m × 0.32 mm, df 5.00 μm
Sinónimos:
GC column, SPB-5, 5% diphenyl
Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización
About This Item
Productos recomendados
material
fused silica
Quality Level
agency
meets requirements for USP G27 and G36
parameter
-60-300 °C temperature (isothermal or programmed)
Beta value
16
df
5.00 μm
technique(s)
gas chromatography (GC): suitable
L × I.D.
50 m × 0.32 mm
matrix active group
Bonded; poly(5% diphenyl/95% dimethyl siloxane) phase
column type
capillary non-polar
¿Está buscando productos similares? Visita Guía de comparación de productos
General description
Aplicación: Esta columna no polar de uso general proporciona principalmente un orden de elución por punto de ebullición con un ligero aumento en la selectividad, en especial para los compuestos aromáticos.
Código USP: Esta columna cumple los requisitos G27 y G36 de la USP .
Fase:
Código USP: Esta columna cumple los requisitos G27 y G36 de la USP .
Fase:
- Ligada
- Poli(difenil al 5 %/dimetil siloxano al 95 %)
- ≤0,32 mm D.I., <2 μm: de -60 °C a 320 °C (isotérmica o programada)
- ≤0,32 mm D.I., ≥2 μm: de -60 °C a 300 °C (isotérmica o programada)
- ≥0,53 mm D.I., <2 μm: de -60 °C a 300 °C (isotérmica ) o 320 °C (programada)
- ≥0,53 mm D.I., ≥2 μm: de -60 °C a 260 °C (isotérmica ) o 280 °C (programada)
Application
SPB®-5 capillary GC column was suitable to investigate high recoveries of polycyclic aromatic hydrocarbons (PAHs) during preparative capillary gas chromatography-mass spectrometry. It may also be used for herbicide determination using In-tube Solid-phase microextraction (SPME).
Other Notes
We offer a variety of chromatography accessories including analytical syringes
Legal Information
SPB is a registered trademark of Merck KGaA, Darmstadt, Germany
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Journal of chromatography. A, 996(1-2), 163-172 (2003-07-02)
Operation parameters of a preparative capillary gas chromatography (pcGC) system were optimized to facilitate clean and efficient harvesting of individual polycyclic aromatic hydrocarbons (PAHs) for subsequent compound-specific radiocarbon analysis. For PAHs, the recommended optimized settings of the specially-designed pcGC cooled
Journal of chromatography. A, 999(1-2), 103-121 (2003-07-30)
Liquid-liquid extraction or solid-phase extraction followed by gas chromatography (GC) or high-performance liquid chromatography are traditional herbicide residue determination methods for environmental samples. Solid-phase microextraction (SPME) is a solventless, fast, and sensitive alternative herbicide residue extraction method that can be
Veterinarni medicina, 37(8), 471-478 (1992-08-01)
Occurrence of individual polychlorinated biphenyl (PCB) congeners in the environment, foodstuffs and other biological materials was assessed. Analysis of specific PCB congeners (28, 52, 101, 138, 153, 180), occurring in animal raw materials and foodstuffs most frequently, has been implemented.
Talanta, 106, 14-19 (2013-04-20)
4-Methylsterols and 4,4-dimethylsterols of 47 samples of subcutaneous fat from Iberian pigs reared on two different fattening systems, "Extensive" and "Intensive", have been analyzed by GC-MS and GC-FID. The lipids were extracted by melting the subcutaneous fat in a microwave
Development of a passive sampler to measure personal exposure to gaseous PAHs in community settings.
Environmental science & technology, 40(19), 6051-6057 (2006-10-21)
A sensitive, simple, and cost-effective passive sampling methodology was developed to quantify personal exposure to gaseous polycyclic aromatic hydrocarbons (PAHs). A Fan-Lioy passive PAH sampler (FL-PPS) is constructed from 320 sections of 1-cm long SPB-5 GC columns (0.75-mm i.d. and
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico