Saltar al contenido
Merck

139386

Sigma-Aldrich

Hexano

Hexane
1 of 1 reviewers received a sample product or took part in a promotion

≥99%, suitable for GC/MS, suitable for EPA 1613, ReagentPlus®

Sinónimos:

n-Hexano

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
CH3(CH2)4CH3
Número de CAS:
Peso molecular:
86.18
Beilstein:
1730733
Número CE:
Número MDL:
Código UNSPSC:
12352001
ID de la sustancia en PubChem:
NACRES:
NA.06
Ensayo:
≥99%
técnicas:
GC/MS: suitable
bp:
69 °C (lit.)
presión de vapor:
256 mmHg ( 37.7 °C)
5.2 psi ( 37.7 °C)
~132 mmHg ( 20 °C)
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Nombre del producto

Hexano, ReagentPlus®, ≥99%

Agency

suitable for EPA 1613

Nivel de calidad

densidad de vapor

~3 (vs air)

presión de vapor

256 mmHg ( 37.7 °C)
5.2 psi ( 37.7 °C)
~132 mmHg ( 20 °C)

Línea del producto

ReagentPlus®

Ensayo

≥99%

Formulario

liquid

temp. de autoignición

453 °F

lim. expl.

7.7 %

técnicas

GC/MS: suitable

índice de refracción

n20/D 1.375 (lit.)

pH

7

bp

69 °C (lit.)

mp

−95 °C (lit.)

solubilidad

water: insoluble

densidad

0.659 g/mL at 25 °C (lit.)

cadena SMILES

CCCCCC

InChI

1S/C6H14/c1-3-5-6-4-2/h3-6H2,1-2H3

Clave InChI

VLKZOEOYAKHREP-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Hexane is an alkane and exists in 5 structural isomeric forms, i.e. hexane, isohexane, 3-methylpentane, neohexane and 2,3-dimethylbutane. It can be obtained from petroleum by distillation. It can also be produced by electrolyzing the potassium butyrate solution. It is widely employed organic solvent for the dissolution and isolation of fats and oils.[1]

Aplicación

Hexane may be used in the following studies:
  • Preparation of graft-copolymer chains of poly-(dimethylsiloxane)-g-poly(methyl methacrylate).[2]
  • GC/MS (Gas Chromatography/Mass Spectrometry) characterization of essential oils isolated from various origins.[3]
  • As solvent for the preparation of samples and standards during chromatographic studies.[4]

Hexane may be used as a solvent in the detection of rubrene, using normal phase high performance liquid chromatography.[5] It may also be used as an extraction solvent to concentrate the analytes like synthetic cannabinoids of the aminoalkylindole type and methanandamide in serum, followed by separation using liquid chromatography coupled with tandem-mass spectrometry.[6]

Información legal

ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany

Palabra de señalización

Danger

Clasificaciones de peligro

Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

Órganos de actuación

Central nervous system, Nervous system

Código de clase de almacenamiento

3 - Flammable liquids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

-7.6 °F - closed cup

Punto de inflamabilidad (°C)

-22 °C - closed cup


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Slide 1 of 4

1 of 4

Occurrence, mechanisms and analytical applications of electrogenerated chemiluminescence. A review
Knight.WA and Greenway.MG et al.
Analyst, 119(5), 879- 890 (1994)
Development and validation of a liquid chromatography?tandem mass spectrometry method for the quantitation of synthetic cannabinoids of the aminoalkylindole type and methanandamide in serum and its application to forensic samples
Dresen S, et al.
Journal of Mass Spectrometry : Jms, 46(2), 163-171 (2011)
G Di Nicola et al.
Journal of chromatography. A, 1190(1-2), 120-126 (2008-03-18)
Biodiesel (a mixture of fatty acid esters) is normally analyzed using gas chromatography/flame ionization detection, as specified by the ASTM D6584 and EN14105 standards. This paper proposes a binary gradient method for analyzing biodiesel mixtures using non-aqueous reverse phase HPLC
Comparative evaluation of 11 essential oils of different origin as functional antioxidants, antiradicals and antimicrobials in foods.
Sacchetti G, et al.
Food Chemistry, 91(4), 621-632 (2005)
Eagleson M.
Concise Encyclopedia Chemistry, 492-492 (1994)

Contenido relacionado

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Questions

1–3 of 3 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. Does this product meet the below spec? trace benzene <0.05 mg/kg it's quite important for our purchase plan

    1 answer
    1. This product is not tested for trace benzene. Please see the specification sheet for this product which lists the tests performed on the product: https://www.sigmaaldrich.com/specification-sheets/427/859/139386-BULK_______SIGALD_____.pdf

      Helpful?

Reviews

1 of 1 reviewers received a sample product or took part in a promotion

Active Filters

    • Review 1
    • Votes 0
    5 out of 5 stars.

    Up to spec, high quality

    The n-Hexane met all specs and enabled reproducible tech transfer for analytical methods.

    Helpful?

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico